Chapter 1
Performing General Administrative Tasks
23
The command usage is as follows:
flashupdate [-s
IP-address
-f
pathname
] [-v]
■
-s
IP-address
is the IP address of any system on the network that can access the
flash image.
■
-f
pathname
is the full pathname to the flash image.
■
-v
is the flag to turn on verbose message output.
5. Reset the system controller.
After the flash has been updated, you must reset the system controller for the new
image to take effect. To reset the system controller, issue the
resetsc
command.
When you issue this command, you will be prompted to confirm that you want to
reset the system controller. Reply
y
when prompted.
Note –
To bypass the confirmation prompt, you can use the
-y
flag with the
resetsc
command. If
resetsc
is issued from a Telnet session, upon reset the
Telnet session will be terminated. The output from the reset will be displayed on the
serial console on the system controller.
sc>
flashupdate -s 129.
xxx
.
xx
.
xx
-f / net/
server_name
/
directory_path
/
combined-OSP-image-1.0.7
Username:
debug
Password:
password
............................................................... .
Update complete. Reset device to use new image.
sc>
sc>
resetsc
Are you sure you want to reset the SC [y/n]?
y
User Requested SC Shutdown
Содержание Sun Fire V215
Страница 6: ...vi Sun Fire V215 and V245 Servers Administration Guide September 2006...
Страница 8: ...viii Sun Fire V215 and V245 Servers Administration Guide September 2006...
Страница 10: ...x Sun Fire V215 and V245 Servers Administration Guide September 2006...
Страница 16: ...xvi Sun Fire V215 and V245 Servers Administration Guide September 2006...
Страница 44: ...28 Sun Fire V215 and V245 Servers Administration Guide September 2006...
Страница 48: ...32 Sun Fire V215 and V245 Servers Administration Guide September 2006...