Sun Enterprise 220R Server Owner’s Guide • October 1999
OBDiag Configuration Variable Settings
The following table provides information about OpenBoot PROM configuration
variables that affect the operation of OBDiag. Use the
printenvs
command to show
current values and the
setenv
command to set or change a value.
Variable
Setting
Description
Default
diag-level
off
No tests are run at power up
min
Performs minimal testing of core functionality
min
max
Runs exhaustive tests for all functions except
external loopbacks. External loopback tests are
run only if
diag-targets
is set to
loopback
,
loopback3
,
device&loopback
, or
device&loopback,3