16
Sun Blade X6250 Server Module Installation Guide • May 2009
Accessing and Configuring the ILOM
Service Processor
The server module includes a service processor (SP) integrated into the
motherboard.
This section provides instructions for:
■
Displaying the SP’s IP address. See
“To Display the Service Processor’s IP
Address” on page 18
.
■
Accessing the SP. See
“To Connect to the ILOM Web Interface” on page 19
and
“To Connect to the ILOM CLI” on page 20
.
■
Configuring the SP’s network settings. See
“To Configure the Service Processor’s
Network Configuration:” on page 21
.
Service Processor Overview
The SP’s built-in system management software enables you to monitor and manage
the components installed in your chassis and server modules. Using the SP, you can
configure network information, view and edit hardware configurations, monitor
vital system information, and manage user accounts.
The chassis has its own service processor, called a Chassis Monitoring Module
Integrated Lights Out Manager (CMM ILOM). In addition to providing chassis
management functions, it provides an Ethernet connection to the server module's SP.
This allows you to view and configure the server module's network information
using the CMM ILOM.
The following sections assume that:
■
The chassis is powered up
■
The CMM ILOM is connected to the network and is working correctly
■
The installer has Ethernet access to the same subnet as the CMM ILOM
If these conditions are not present, see the ILOM documentation for your chassis.
Service Processor Versions
Your server module might be equipped with one of several versions of the SP: