Sun StorEdge™ L25 Tape Library and Sun StorEdge™ L100 Tape Library Installation Guide
Document 6423015-01, Ver. 1, Rel. 0
June 2002
Connecting the Library to AC Power
33
Table 5 AC Distribution
Requirements, L100
# of
Library
Modules
Distribution Unit Requirements
200-240V 50-60Hz supply voltage (Europe
& international, etc.)
100-120V 50-60Hz supply voltage (USA,
Canada, Japan, etc.)
1
Connect the library to an AC wall outlet rated
minimum 10A, minimum 1.00mm
2
<HAR>
cord with minimum 10A plug. Must be three
wire grounding plug and wall outlet.
Connect the library to one UL listed AC
distribution unit rated 15A or 20A, with a
minimum 14AWG 3 wire cord, and a 15A or
20A plug. Must be three wire grounding plug
and wall outlet.
2
Connect each library to a separate wall outlet
rated minimum 10A, minimum 1.00mm
2
<HAR> cord with minimum 10A plug. Must
be three wire grounding plug and wall outlet.
Connect both libraries to one UL listed AC
distribution unit rated 15A or 20A, with a
minimum 14AWG 3 wire cord, and a 15A or
20A plug. Must be three wire grounding plug
and wall outlet.
3
Select one of the following options:
• Connect each library to a separate wall
outlet rated minimum 10A, minimum
1.00mm2 <HAR> cord with minimum 10A
plug. Must be three wire grounding plug
and wall outlet.
• Connect all libraries to one AC distribution
unit rated minimum 10A, minimum
1.00mm
2
<HAR> 3 wire cord with 3 wire
IEC60309 rated 16A. Must be 3 wire
grounding plug and wall outlet and have a
ground warning label.
• Connect all libraries to one distribution unit
rated minimum 10A, minimum 1.00mm
2,
<HAR> 3 wire cord permanently wired to
the electrical supply. Must be connected
with a 3 wire cable and have a ground
warning label.
Select one of the following options:
• Connect no more than 2 libraries to each of
two AC distribution units rated 15A or 20A,
with a minimum 14AWG 3 wire cord, and a
15A or 20A plug. Must be 3 wire grounding
plug and wall outlet. The AC distribution
units must be plugged into separate outlets
served by separate circuit breakers or fuses.
• Connect all libraries to one AC distribution
unit rated 20A, with a minimum 14AWG 3
wire cord, with a 20A plug. Must be 3 wire
grounding plug and wall outlet.
• Connect all libraries to one AC distribution
unit rated minimum 20A, with a minimum
14AWG 3 wire cord, permanently wired to
the electrical supply.