background image

Install any required patches or software for Sun StorEdge Traffic Manager software support to nodes
and enable multipathing.

For the procedure about how to install the Sun StorEdge Traffic Manager software, see “How to
Install Sun Multipathing Software” in

Sun Cluster Software Installation Guide for Solaris OS

.

To create a logical volume, see

“How to Create a Logical Volume” on page 17

.

To continue with Sun Cluster software installation tasks, see your Sun Cluster software
installation documentation.

How to Add Storage Arrays to an Existing Cluster

Use this procedure to add a new storage array to a

running

cluster. To install a new storage array in a

Sun Cluster configuration that is not running, use the procedure in

“How to Install Storage Arrays in

a New Cluster” on page 14

.

This procedure relies on the following assumptions:

(VERITAS Volume Manager Only)

You have a version of VERITAS Volume Manager that

includes Array Support Library (ASL). For more information on this requirement, see

“Requirements” on page 11

.

You have enough host adapters to connect the nodes and the storage array to the service
processor panel.

If you need to install host adapters, see

“How to Replace a Host Adapter” on page 27

When this

procedure asks you to replace the failed host adapter, simply install the new host adapter instead.

You do

not

need to install a new node in your cluster.

If you need to add a node to your cluster, see your Sun Cluster system administration
documentation. Ensure that you install the required Solaris patches for storage array support.

Unpack, place, and level the storage array.

For instructions, see the StorageTek online documentation listed in

Table P–2

.

(Optional) Install the Fibre Channel (FC) switch for the storage array if you do not have a switch
installed.

For the procedure about how to install an FC switch, see the documentation that shipped with your
FC switch hardware.

Connect the nodes to the service processor panel.

(SAN Configuration)

Connect the FC switches to the service processor panel.

(Direct-Attached Configuration)

Connect each node to the service processor panel directly.

For instructions, see the StorageTek documentation listed in

“Related Documentation” on page 6

.

2

See Also

Before You Begin

1

2

3

Installing Storage Arrays

Sun Cluster 3.0 - 3.1 with StorageTek Fibre Channel RAID Arrays Manual for Solaris OS • July 2006, Revision A

16

Содержание StorageTek 6140

Страница 1: ...Sun Cluster 3 0 3 1 with StorageTek Fibre Channel RAID Arrays Manual for Solaris OS Sun Microsystems Inc 4150 Network Circle Santa Clara CA95054 U S A Part No 819 6676 10 July 2006 RevisionA...

Страница 2: ...fs la technologie incorpor e dans le produit qui est d crit dans ce document En particulier et ce sans limitation ces droits de propri t intellectuelle peuvent inclure un ou plusieurs brevets am ricai...

Страница 3: ...Existing Cluster 16 Con guring StorageArrays 17 How to Create a Logical Volume 17 How to Remove a Logical Volume 19 3 Maintaining a StorageTekArray 23 FRUs That Do Not Require Sun Cluster Maintenance...

Страница 4: ...Index 31 Contents Sun Cluster 3 0 3 1 with StorageTek Fibre Channel RAIDArrays Manual for Solaris OS July 2006 RevisionA 4...

Страница 5: ...platforms SPARC and x86 The information in this document pertains to both platforms unless otherwise speci ed in a special chapter section note bulleted item gure table or example This book assumes th...

Страница 6: ...e and applications If you plan to use this documentation in a hardcopy format ensure that you have these books available for your reference The following Sun Cluster books support the Sun Cluster 3 1...

Страница 7: ...r Data Services Developer s Guide for Solaris OS System administration Sun Cluster System Administration Guide for Solaris OS Error messages Sun Cluster Error Messages Guide for Solaris OS Command and...

Страница 8: ...nformation about peripheral devices psrinfo v Displays information about processors showrev p Reports which patches are installed prtdiag v Displays system diagnostic information usr cluster bin scins...

Страница 9: ...is a copy that is stored locally Do not save the le Note Some emphasized items appear bold online Shell Prompts in Command Examples The following table shows the default UNIX system prompt and superu...

Страница 10: ...10...

Страница 11: ...uster environment with storage that is using LUN masking the StorageTekTM array must also implement LUN masking Restrictions When using storage based replication do not con gure a replicated volume as...

Страница 12: ...12...

Страница 13: ...Related Documentation on page 6 For a URLto this storage documentation see Related Documentation on page 6 Installing StorageArrays This section contains the procedures listed in Table 2 1 TABLE 2 1 T...

Страница 14: ...on guration Node 1 Node 2 Switch Switch Controller module Expansion tray FIGURE 2 2 StorageTekArray Switched Con guration How to Install StorageArrays in a New Cluster Use this procedure to install a...

Страница 15: ...anel SAN Con guration Connect the FC switches to the service processor panel Direct Attached Con guration Connect each node to the service processor panel directly For instructions see the StorageTek...

Страница 16: ...ge array to the service processor panel If you need to install host adapters see How to Replace a HostAdapter on page 27 When this procedure asks you to replace the failed host adapter simply install...

Страница 17: ...eArrays This section contains the procedures about how to con gure a storage array in a running cluster Table 2 2 lists these procedures TABLE 2 2 Task Map Con guring a StorageArray Task Information C...

Страница 18: ...set up the logical volume When you are nished the volume must be created mapped mounted and initialized If necessary partition the volume To allow multiple clusters and nonclustered nodes to access th...

Страница 19: ...OS To create a new resource or con gure a running resource to use the new logical volume see Chapter 2 Administering Data Service Resources in Sun Cluster Data Services Planning and Administration Gu...

Страница 20: ...ice DiskSuite Solaris Volume Manager or VERITAS Volume Manager documentation Note Volumes that were managed by VERITAS Volume Manager must be completely removed from VERITAS Volume Manager control bef...

Страница 21: ...uide for Solaris OS On Node A remove the paths to the logical volume that you removed Remove obsolete device IDs devfsadm C scdidadm C For each additional node that is connected to the shared storage...

Страница 22: ...22...

Страница 23: ...s see the StorageTek documentation listed in Related Documentation on page 6 FRUs That Do Not Require Sun Cluster Maintenance Procedures In general the following is a list of administrative tasks that...

Страница 24: ...e to Switch Component in a Cluster Without Multipathing on page 27 Replace a node s host adapter How to Replace a HostAdapter on page 27 Replace a disk drive How to Replace a Disk Drive on page 29 Add...

Страница 25: ...that you upgraded are visible to all nodes luxadm probe Restart all I O to the storage arrays You stopped I O to these storage arrays in Step 1 How to Remove a StorageArray Use this procedure to perm...

Страница 26: ...assumes that except for the component you are replacing your cluster is operational Ensure that you are following the appropriate instructions If your cluster uses multipathing see How to Replace a No...

Страница 27: ...t are running on Node A scstat Move all resource groups and device groups to another node scswitch s h from node Replace the node to switch component Refer to your hardware documentation for any compo...

Страница 28: ...roups that are running on Node A Record this information because you use this information in Step 9 of this procedure to return resource groups and device groups to Node A scstat Move all resource gro...

Страница 29: ...A scswitch z g resource group h nodename scswitch z D device group name h nodename For more information see your Sun Cluster system administration documentation How to Replace a Disk Drive Use this pr...

Страница 30: ...nistration documentation Did you detach a submirror or plex in Step 1 If no you are nished with this procedure If yes use volume manager commands to reattach the submirror or plex For more information...

Страница 31: ...volume groups 17 D deleting logical volumes See removing logical volumes disk drives adding 23 removing 24 replacing 29 30 E Ethernet cables replacing 23 F rmware upgrade storage array rmware 24 25 F...

Страница 32: ...placing chassis 23 controllers 23 cooling units 23 disk drives 29 30 Ethernet cables 23 host adapters 27 29 midplane 23 node to switch components 26 27 power cables 23 power supplies 23 power units 23...

Отзывы: