Chapter B
Using DC Power
47
Caution –
Potential data loss – Moving a array or array components that are
configured as part of a volume group can result in data loss. To prevent data loss,
always consult a Customer Support representative before relocating configured
drives, controller trays or expansion trays.
Note –
Trays in arrays can be connected to the DC power supply (–48 VDC). Before
turning off any power switches on a DC-powered tray, you must disconnect the two-
pole 20-amp circuit breaker.
Do not move controller trays or expansion trays that are part of a volume group
configuration. If you must move array components, contact a Customer Support
representative for procedures. A Customer Support representative might direct you
to complete several tasks prior to undertaking the relocation. These tasks might
include:
■
Creating, saving, and printing an array profile of each storage array that is
affected by the relocation of a drive or tray.
■
Performing a complete backup of all data on the drives that you intend to move.
■
Verifying that the volume group and each of its associated volumes on the
affected array have an Optimal status.
■
Determining the location and status of any global hot spares associated with the
affected storage array.
Содержание StorageTek 6140 Array
Страница 5: ...Contents v Installing a Tray in a Telco 2 Post Rack 55...
Страница 6: ...vi Sun StorageTek 6140 Array Release Notes November 2008...
Страница 8: ...viii Sun StorageTek 6140 Array Release Notes November 2008...
Страница 42: ...34 Sun StorageTek 6140 Array Release Notes November 2008...
Страница 46: ...38 Sun StorageTek 6140 Array Release Notes November 2008 FIGURE A 3 Incorrect Way to Insert Disk Drive...
Страница 56: ...48 Sun StorageTek 6140 Array Release Notes November 2008...
Страница 61: ...Chapter C Preparing the Two Post Telco Rack 53 FIGURE C 3 Inserting Screws in the Lower Mounting Holes...