26
Sun StorageTek 6140 Array Release Notes • November 2008
Controller Cache Memory Size Displays
0
Bug 6747153
– When running controller firmware version 07.xx.xx.xx, both the GUI
and command line interface (CLI) versions of the array management software report
0
for cache memory size.
Workaround
– The following serial command can be used to gather the cache size:
rpaGetMemorySizeMB
Addition and Removal of Initiators From Zones in Fabric Are Not
Dynamically Detected
Bug 6329784
- When an initiator is added or removed from a zone in a fabric, the
configuration software does not dynamically detect the change. The WWNs of
initiators newly added to the SAN are not displayed.
Workaround –
If the WWN of a new initiator is not in the drop-down list on the
New initiator page, try creating the initiator by manually entering the new WWN.
This will force the page to refresh. When you create another new initiator, the WWN
will be in the list.
Cannot Boot From System With a 6768A Direct Attached HBA
Bug 6358173
- The 6768A (QLogic 2342) 2-Gb dual-port adapter cannot be used in
direct attach mode, and you cannot boot from it.
Workaround
- To use 6768A in direct attach mode, move the jumpers from pins 2-3
to pins 1-2. To boot using this HBA, move the 6768A jumpers from pins 2-3 to pins
1-2 or put a switch between the host and array.
Errors From IOM 2A and 2B Ports
Bug 6417872
- When Small Form-factor Plugs (SFPs) are installed into the I/O
Module (IOM) 2A and 2B ports, the front amber fault LED lights and the IOM
displays an H8 error.
Workaround -
Do not install SFPs into these slots; they are reserved for future use.
Documentation Issues
This section describes known issues and bugs related to the Sun StorageTek 6140
Array documentation.
Содержание StorageTek 6140 Array
Страница 5: ...Contents v Installing a Tray in a Telco 2 Post Rack 55...
Страница 6: ...vi Sun StorageTek 6140 Array Release Notes November 2008...
Страница 8: ...viii Sun StorageTek 6140 Array Release Notes November 2008...
Страница 42: ...34 Sun StorageTek 6140 Array Release Notes November 2008...
Страница 46: ...38 Sun StorageTek 6140 Array Release Notes November 2008 FIGURE A 3 Incorrect Way to Insert Disk Drive...
Страница 56: ...48 Sun StorageTek 6140 Array Release Notes November 2008...
Страница 61: ...Chapter C Preparing the Two Post Telco Rack 53 FIGURE C 3 Inserting Screws in the Lower Mounting Holes...