Removing and Replacing System Boards and Assemblies
2-7
2
3. Hold the card by the edges nearest to the connector, and gently rock the
card back and forth to loosen it from the socket.
Caution – The connector housing will break if the card is tilted too far.
4. Lift the card at an angle while guiding the face plate out of the back panel
opening and under the springfingers. Refer to Figure 2-6.
Figure 2-6
Removing or Installing an SBus Card
5. Place the SBus card in an antistatic bag.
6. If a replacement card is not available, install a filler panel (P/N 340-2305)
on the back panel opening of the system board. Secure the panel with the
screws that were removed in step 1.
Caution – Ensure the panel is right-side up. If the filler panel is installed
upside down, a gap will be created, impairing system cooling.
!
SBus card
Springfingers
!