Sun Secure Application Switch – Release Notes for v3.2.1
23
Displaying statistics using line graphs will preserve all history of graphed data,
which will continuously consume memory on your PC if left unattended.
(2299/6351855)
Using the Web Interface, the dashboard has a slow memory leak, which is also
present after the session times out due to inactivity. If the GUI is left open for long
periods of time, such as overnight, this may cause workstation performance to
deteriorate until the browser window is closed. (5927/6351858)
Online Help requires that JavaScript
TM
is enabled on your Web browser.
(2104/1351860)
Configuration Scaling
Management
System vSwitch:
■
One management vRouter
■
Four shared vRouters
■
100 user accounts (used for login access to the switch)
■
10 concurrent CLI sessions
■
10 concurrent HTTP management sessions
Virtualization
User-defined vSwitches:
■
One user-defined vSwitch for the N2120, N2040, and N1400
■
Ten user-defined vSwitches, with the optional virtualization key on the N2120,
N2040, and N1400
L2 to L3 Scale
■
Ports per LAG: 16
■
LAGs: 22
■
Ports or LAGs: 44 per VLAN