7-1
C H A P T E R
7
Removing and Replacing Cold-
Swappable Subassemblies
Following are the cold-swappable subassemblies for the Netra CT 820 server:
■
“Removing and Installing the Rear Transition Card for the Distributed
Management Card” on page
■
“Removing and Installing the Midplane” on page
7.1
Removing and Installing the Rear
Transition Card for the Distributed
Management Card
The rear transition card for the distributed management card is not a hot-swappable
component; you must fully power-off the system before removing the rear transition
card. However, the distributed management card itself is a hot-swappable card, with
some restrictions. Refer to
for more information.
7.1.1
Removing a Rear Transition Card for the
Distributed Management Card
1. Turn off the system and disconnect it from power.
Refer to
2.2, “Powering Off the Server” on page
.
Содержание Netra CT 820
Страница 7: ...Contents vii Index Index 1...
Страница 8: ...viii Netra CT 820 Server Service Manual July 2004...
Страница 18: ...xviii Netra CT 820 Server Service Manual July 2004...
Страница 22: ...1 4 Netra CT 820 Server Service Manual July 2004...
Страница 28: ...2 6 Netra CT 820 Server Service Manual July 2004...
Страница 46: ...4 16 Netra CT 820 Server Service Manual July 2004...
Страница 72: ...6 8 Netra CT 820 Server Service Manual July 2004...
Страница 80: ...7 8 Netra CT 820 Server Service Manual July 2004...
Страница 84: ...8 4 Netra CT 820 Server Service Manual July 2004...
Страница 118: ...A 34 Netra CT 820 Server Service Manual July 2004...
Страница 128: ...Glossary 4 Netra CT 820 Server Service Manual July 2004...
Страница 132: ...Index 4 Netra CT 820 Server Service Manual July 2004...