100
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • August 2004
▼
To Set Autonegotiation to
off
for Other
Noncompliant Network Equipment
If your network equipment does not support autonegotiation, you can set
autonegotiation to
off
on the GigaSwift Ethernet (
ce
) device.
1. Set the following GigaSwift Ethernet driver parameters to values according to the
documentation that shipped with your switch:
■
adv-1000fdx-cap
■
adv-1000hdx-cap
■
adv-ampause-cap
■
adv-pause-cap
2. Set the
adv-autoneg-cap
parameter to
0
.
Note –
See Chapter 4 for the default values of these parameters and for instructions
on how to set these parameters.
Failure to Configure GigaSwift Ethernet Instance
If your machine fails to configure a GigaSwift Ethernet instance, yet
prtconf
indicates the adapter is present, the problem might be due to residue adapter
instances in the
path_to_inst
file.
To solve this problem, open the
path_to_inst
file for editing and remove the lines
containing
ce
device path.
Reboot the machine and try to configure it again.
Содержание GCS
Страница 8: ...viii Sun GigaSwift Ethernet Adapter Installation and User s Guide August 2004 ...
Страница 18: ...x Sun GigaSwift Ethernet Adapter Installation and User s Guide August 2004 ...
Страница 58: ...36 Sun GigaSwift Ethernet Adapter Installation and User s Guide August 2004 ...
Страница 90: ...68 Sun GigaSwift Ethernet Adapter Installation and User s Guide August 2004 ...
Страница 100: ...78 Sun GigaSwift Ethernet Adapter Installation and User s Guide August 2004 ...
Страница 110: ...88 Sun GigaSwift Ethernet Adapter Installation and User s Guide August 2004 ...
Страница 114: ...92 Sun GigaSwift Ethernet Adapter Installation and User s Guide August 2004 ...