Brocade Silkworm 3200, 3250, 3800, 3850, 3900, 12000, and 24000 Switches Rackmounting Guide
43
FIGURE 4-19
Securing the
Director to the
Sun StorEdge 72-Inch Expansion Cabinet or the Sun Fire Cabinet
The Brocade SilkWorm 12000/24000 director mounting flange holes must line up
with the cabinet vertical mounting surface holes.
6. Tighten the ten 10-32 x 1/2-in. pan-head screws to a torque of 25 inch-pounds (28.8
cm-kgs) on each side of the director mounting flange to the vertical mounting
surface of the cabinet.
Note –
Do not replace the director front door.
7. To ensure the proper cooling air flow, remove any filler panels on the front of the
cabinet that are directly in front of the director.
10-32 x 1/2-in. pan-head screws