Brocade Silkworm 3200, 3250, 3800, 3850, 3900, 12000, and 24000 Switches Rackmounting Guide • October 2004
2. Install the rackmount brackets on the inner slide rail by performing the following
steps.
These rackmount brackets prevent the switch from sliding all the way out of the rack
in the event the rack is accidentally moved.
Note –
To meet air flow requirements, the 3800 switch is mounted with the port side
facing the back of the cabinet (rack).
a. Position a rackmount bracket at the end of one of the inner slide rails (the end
that does not contain the lock release lever), as shown in
.
b. Attach the rackmount bracket to the slide rail using two of the slotted head
8-32 x 3/8-inch screws, with a lock nut on the end of each screw.
c. Tighten the screws to a torque of 15 inch-pounds (17.3 cm-kgs).
d. Repeat Steps a through c with the second inner slide rail.
3. Attach two of the three-hole extension slide mount L-brackets to each outer slide
rail.
a. See
. Use two of the slotted head 8-32 x 3/8-inch screws per L-bracket,
with the screw heads on the inside of the slide rails and a lock nut on the end
of each screw.
b. Tighten the screws to a torque of 15 inch-pounds (17.3 cm-kgs).
4. Install the inner slide rails to the 3800 switch chassis by performing the following
steps.
a. Position one of the inner slide rails with the flat side against the 3800 switch.
To allow the power supply side of the 3800 switch to slide out the front of the
rack, orient the rail as shown in
, with the end containing the lock
release lever towards the port side of the 3800 switch.
b. Attach the rail to the 3800 switch by using the Phillips 8-32 x 3/16-inch screws.
Caution –
Using screws longer than 3/16-inch on the 3800 switch chassis can
damage the 3800 switch.
c. Tighten the screws to a torque of 15 inch-pounds (17.3 cm-kgs).
d. Repeat Steps a and b with the second inner slide rail on the other side of the
3800 switch.