Chapter 3
System Setup
en-23
2. Connect the AC power cord to the right power inlet labeled 1 at the back of the
system.
3. Connect the other end of the AC power cord to the power sequencer in the rack
enclosure or to an AC outlet.
See the instructions provided with your rack enclosure for information about the
power sequencer. The outlet must connect the system to a 15A circuit in North
America and Japan, and to a 10A circuit in Europe.
Note –
If your server includes a second power supply, connect the second AC
power cord to the left power inlet labeled 2. You may connect the second power
supply to the same AC circuit as the first supply. However, for increased system
redundancy, you should connect the two power supplies to separate circuits.
Note –
This system is suitable for use with IT Power Systems.