8. Flip the Molex tool over and use the tube in attempt to straighten the pin.
If the pin cannot be straightened satisfactorily, or might break if straightened,
replace it.
9. Remove the pin following
10. If the pin is too bent for the Molex tool, see
Needle-Nose Pliers” on page 56
.
▼
To Remove a Pin With Needle-Nose Pliers
Perform this procedure only when the Molex tool is incapable of removing the pin.
You need micro-tipped needle-nose pliers.
1. With one hand, grasp the pin with the very tip of the needle-nose pliers.
2. Squeeze the pliers sufficiently to grip the pin for extraction.
3. With the other hand, steady the pliers in a position for perpendicular
extraction.
See
FIGURE 7-7
Using Pliers to Pull a Pin