background image

Inspection

We recommend an inspection of the Self Contained toilet prior to installation and to make sure you have
received all of the parts required as listed below.

- 4 -

Inspecting the unit for 
damage

What’s in the Box

Familiarise
Yourself with the
Self Contained Toilet

Attaching 
and 
Detaching 
the 
footrest
(EXCEL units 

i

)

 

 

If there is any visible damage to the carton- 

The contents of the carton should be inspected before signing the bill of lading.
Damaged units should be refused. Call Sun-Mar immediately.

ii)  If the shipper has left-                                                     

Report the damage immediately to the transport company and call Sun-Mar.

iii)  Soon after delivery, remove the Self Contained Toilet carefully 

from the carton- If there is hidden damage, or for any service Questions,
contact  Sun-Mar to determine the best course of action.

1- Owners Manual

1- Warranty Card

1- Bowl Liner

1- 6” Diffusor (NE)

3- 4”x31” Vent Pipes (NE) 

1- Excel/Compact Hardware Kit    1- Rake
1- Footrest (EXCEL & EXCEL NE)  1- 2” Pipe Insulation (Electric)
1- 1” x 8’4” Drain Hose (NE)

1- 4” Diffusor  (Electric)

1- Compost Sure Green               4- 2”x31” Vent pipe (electric)
i)   Turn the drum handle clockwise to rotate the patented Bio-Drum for mixing and

aeration. (The drum rotates counter-clockwise and the drum door closes). TThhiiss

iiss  hhooww  yyoouu  wwiillll  rroottaattee  tthhee  ddrruum

m  dduurriinngg  rreegguullaarr  ooppeerraattiioonn..

ii)  Pull the drum locker button, (located under the footrest) and turn the handle 

counter-clockwise to simulate removal of compost. TThhiiss  iiss  hhooww  yyoouu  wwiillll  rreem

moovvee  

ccoom

mppoosstt  dduurriinngg  rreegguullaarr  ooppeerraattiioonn..

iii) Plug the unit’s electrical cord (Electric) into a standard three-prong electrical 

outlet, and feel the air movement from the vent outlet at the front of the unit to 
ensure the vent system is  working properly.

iv)  Pull out the compost finishing drawers at the bottom  right of the unit. After 

the unit has been plugged in for ten minutes, place a hand on the floor of the    
evaporating chamber (the area under 
the finishing drawer) to check it is warm to the touch, and that the heater is working 
properly.

The footrest attaches to the unit with the metal track above the
finishing drawer opening. To attach the footrest,

incline 

the

footrest at a 45 degree angle to the floor as shown. Insert the
round top edge of the track on the footrest into the round top
edge of the metal track on the unit and then lower the footrest
to the floor. NNoottee::  FFoooottrreesstt  m

muusstt  bbee  ccoorrrreeccttllyy  aattttaacchheedd  bbeeffoorree

sstteeppppiinngg  oonn  iitt..

Содержание Excel CSEL-01001

Страница 1: ...quid containment odours and solid end products in both residential and cottage use RATED CAPACITY Residential Continuous Use EXCEL 3 Adults or a family of 5 or EXCLE NE Units 2 Adults or families of 3...

Страница 2: ...hite 115 V CSEL 01001 230 Excel Bone 230 V CSEL 01001W 230 Excel White 230 V CSNL 01101B Excel NE Bone CSNL 01101W Excel NE White CSEM 01400B Compact Bone CSEM 01400WB Compact White CSEM 01400BB Compa...

Страница 3: ...on n Space requirements Vent Piping Location Leading the vent through the Roof The Diffusor Drain Installation Handling Effluent Start Up and Use Ongoing Toilet Maintenance 2 3 3 3 3 4 4 4 4 4 5 7 5...

Страница 4: ...res below 55 F 13 C additional heat is required if the composting toilet will be used continually or frequently If used for intermittent cottage application 3 4 weekends throughout the cold season no...

Страница 5: ...provides the necessary mass to maintain good compost and allows easy aeration of the compost by simply turning the drum Excess liquid will exit through a screen in the bottom of the drum into the eva...

Страница 6: ...s s iis s h ho ow w y yo ou u w wiillll r ro ot ta at te e t th he e d dr ru um m d du ur riin ng g r re eg gu ulla ar r o op pe er ra at tiio on n ii Pull the drum locker button located under the foo...

Страница 7: ...Installation EXCEL and EXCEL NE ROUGH IN DIMENSIONS COMPACT ROUGH IN DIMENSIONS 5...

Страница 8: ...s exposed to the outside or in a non heated space should be insulated if using the unit during cold weather 3 INSTALL VENT SO THAT IT TERMINATES 24 30 ABOVE HIGHEST PEAK OF THE ROOF 4 If you will be i...

Страница 9: ...pipe The diffusor design encourages updraft and discourages wind and weather from going down the vent stack We do not recommend installing anything else on the top of the vent as it could impede the...

Страница 10: ...nds THERE SHOULD BE NO HORIZONTAL SECTIONS OF VENT 3 INSTALL VENT SO THAT IT TERMINATES 24 30 ABOVE HIGHEST PEAK OF THE ROOF If the vent is being installed on a steeply pitched roof where snow shear m...

Страница 11: ...usor design encourages updraft and discourages wind and weather from going down the vent stack We do not recommend installing anything else on the top of the vent as it could impede the venting Unlike...

Страница 12: ...seat The Self Contained toilet is now ready for use Step 4 For electric units only The fan will run continuoulsy 24 hours per day 120 Volt Use Plug it in to a three prong electrical outlet 240 Volt Us...

Страница 13: ...be open under the toilet seat ready to receive waste A Ad dd d o on ne e s sc co oo op p o of f M Miic cr ro ob be e M Miix x to the patented bio drum to recharge the pile This will help to ensure yo...

Страница 14: ...d for 3 4 weekends throughout the winter season then it is considered occasional use All of the same considerations should be taken with these units to winterize them When the temperature dips below 5...

Страница 15: ...e counter clockwise until the handle hits a hard stop Open the drawer and use your rake to level the com post Compost should now be allowed to rest in the drawer for 3 4 weeks to finish the composting...

Страница 16: ...We do not recommend adding kitchen or garden scraps 1 To eliminate flies you can use any pesticide that is used on your garden Pesticides used for garden use are not anti bacterial so are safe to use...

Страница 17: ...t is installed above the peak of the roof If not extend the vent Guide wires may be necessary 2 Add lime to the evaporation chamber as much as you think necessary You will have to rake more often if y...

Страница 18: ...through the overflow drain by tipping the unit up make sure overflow is hooked up first 1 Rake peat moss away from the safety drains This is the build up area If drains are still clogged proceed to s...

Страница 19: ...ions are included with the replacement part Check fuse located on the electric box to ensure that it is functioning correctly If the wire in the fuse is chared or broken Replace the fuse Rotate EXCEL...

Страница 20: ...ift the toilet seat Turn the handle 3 revolutions to bring the drum screen to the top of the drum Access can be gained by reaching through the hole under the toilet seat Spray the drum screen with Com...

Страница 21: ...Sun Mar composting toilet and toilet systems Microbe Mix also contains citronella to discourage insects 5 50 00 0g g 1 16 6 o oz z jja ar r w wiit th h s sc co oo op p Bulking material containing a m...

Страница 22: ...16 Aluminum Sheet 26 Nylon Drive Gear 7 Compact Drum 17 Thermostat 27 Fan Motor Kit 8 Drum Locker Release 18 Heating Element 28 Toilet Seat Screw 9 Front Bearing Plate 19 Electric Box E Elle ec ct tr...

Страница 23: ...ment Electric 20 Nylon Drive Gear 5 Plastic Drum Door 13 Electric Box Electric 21 EXCEL Top 6 EXCEL Tank 14 Thermostat Assembly Electric 22 Fan Assembly Electric 7 Footrest Channel 15 Emergency Drain...

Страница 24: ...ge or failure resulting from failure of the purchaser to follow normal operating procedure outlined in the Owner s Manual or in any other printed instructions 4 Labour and service charges incurred in...

Отзывы: