SPECIFICATIONS
Model
SH42
SH68
Electrical Input
220/240 volt, 50 hertz,
220/240 volt, 50 hertz,
200 watts IP20
200 watts IP20
Maximum Input, net
44 KW at 1.34 bar
70 KW at 1.34 bar
Minimum Input, net
20 KW at .34 bar
31 KW at .34 bar
Regulator Output (max./min.)
1.34 bar/.34 bar
1.34 bar/.34 bar
Burner Rate
44 KW, 3400 g/hr max.
70 KW, 5400 g/hr max.
20 KW, 1550 g/hr min.
31 KW, 2400 g/hr min.
Supply Pressure (min.)
2 bar
2 bar
Ventilation
1100 cm
2
1750 cm
2
Room Size
440 cubic meters
700 cubic meters
Air Delivery Class
Type A
Type A
Blue
Green
Blue
Green
Green
Blue
Solenoid
Valve
Solenoid
Valve
Motor
Brown
On/Off Switch
Brown
Blue
Green
Terminal
Board
Power
Cord
Blue
Blue
T
Black
Blue
Blue
Black
White
Connector
Connector
Burner
Control
Orange
Ignitor
Thermal
Switch
Brown
Brown
White
Green
Green
Lamp
Green
Yellow
Yellow
Connector
Centrifugal
Switch
Black
WIRING
DIAGRAM
Figure 16 - Wiring Diagram
SH42
Model
Only