EV40 User’s Manual
SPECIFICATIONS
Line Input Power - Service Entrance
Voltage & Wiring
240V AC single-phase - L1, L2, and Safety Ground
208V AC 3-phase, wye-connected - Any 2 phases, and Safety Ground
240V AC 3-phase, delta-connected. With center-tap on one leg, must use
only the two phases on either side of the center-tap. The two phases must
both measure 120V AC to ground.
Do not use the third leg (208V
“stinger”).
Service Conductors
EV40 and EV40P L1, L2, and Safety Ground use 8AWG, 75ºC copper
wire.
Voltage Range
185V AC to 264V AC
Frequency
60 Hz
Current & Output Power
(at 240VAC)
Circuit Maximum Output
EV40 Model Breaker Current Power
EV40 Hardwired 40A 30A 7.2KW
EV40P 14-50 plug 50A 30A 7.2KW
Note that the maximum current for the vehicle is set by the duty cycle of
the Pilot waveform.
Output power is variable depending on the EV40 model and vehicle
demand.
Plugs
Attached NEMA 14-50P plugs is available on the EV40P
Dimensions
Height 500 mm (19.7 in)
Width 225 mm (8.9 in)
Depth 135 mm (5.3 in)
Weight
6.0kg (13lbs)
Cable Length
25 feet
Environment
Operating Temperatures:
-30ºC to +50ºC (-22ºF to +122ºF)
Storage Temperatures:
-40ºC to +80ºC (-40ºF to +176ºF)
Enclosure Rating: NEMA 4 - watertight
Agency Approvals
ETL listed, FCC Part Class B
Page 17