Step 2
3. Attach the "C" clamp portion of the leveling
and supporting device onto the inside of the
elbow. Center the "C" clamp and tighten
securely the fitting attachment screw.
Step 3
4. Pick up fitting with both hands and rest
bottom of fitting onto the two lower jack
bars.
10
Sumner Clamp Champ, Operator’s Manual
CAUTION -
Do not lift fitting by leveling
and supporting device. If the fitting is
too heavy to lift, use a crane or Roust-A-
Bout.
5. Once fitting is resting on jack bar, hook
leveling and supporting device chain onto
notch located behind the main block. Allow
space between pipe and fitting for
adjustment.
6. Remove high-lows by adjusting the jack bar
screws on the high spots.
7. Check alignment by first placing a level on
the fitting opening. Level should be 90
degrees from the run of the pipe. After
rotating the fitting until level, place the
level so that it is in line with the pipe.
Using the support and leveling devices
knob, adjust fitting until level. Once
spaced and leveled, tack fitting onto pipe
and remove clamp.
ARC WELDING SUPPLIES - 07 847 7870