8
INSTALLATION
CAUTION:
During installation, persons installing the hood must wear heavy
gloves to protect against sharp edges.
POSITIONING THE RANGE HOOD
Upon completion of installation, the distance between the hood and an electric
rangetop must be a minimum of 26" (65cm), and the distance between the hood and a
gas rangetop must be a minimum of 30" (75cm).
min. 30" for gas ranges
min. 26" for electric ranges
PREPARING THE SITE
WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY,
OBSERVE THE FOLLOWING:
a. Installation work and electrical wiring must be done by qualified personnel in
accordance with all applicable codes and standards, including re-rated
construction.
b. Sufficient air is needed for proper combustion and exhausting of gases through
the chimney of fuel-burning equipment to prevent back-drafting. Follow the
range manufacturer's guidelines and safety standards such as those published by
the National Fire Protection Association (NFPA), the American Society for
Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local
code authorities.
c. When cutting or drilling into a wall or ceiling, do not damage electrical wiring
and other hidden utilities.
d. Ducted fans must always be vented to the outdoors.