13
The door will
not close
properly.
The appliance is not properly leveled.
The door was reversed and not properly
re-installed.
The gasket is dirty.
The shelves are out of position.
Level the appliance with the
adjustable feet.
Check the door hinge and reassemble
correctly.
Clean the door gasket.
Check the shelves and refit correctly.
Display “E0”,
“E1”. “E2”,
“E3”, “E4”,
“E5” or “E7”.
“E0” indicates a communication error for
3-zone models.
“E1” or “E2” indicates that the air
temperature sensor has failed.
“E3” or “E4” indicates that the defrost
sensor in the evaporator has failed.
“E5” indicates a defrost heater failure.
“E7” indicates a door switch failure.
Call for service.
The alarm
sounds.
The appliance door has been open for
longer than 60 seconds.
Close the door.
The icon “--” is
lit and flashing
in the
temperature
display.
The display temperature is out of range.
Only temperatures within the range
0~99°F/-9~37°C can be displayed. If
the temperature is not within this
range, the icon “--” will be displayed
instead. This is normal.