For models FF6BI, FF6LBI, FF7LBI, FF7LBLBI, SCR600LBI and SCR600BLBI: 

NOTES: See illustration below.  
               All of the parts that are removed must be kept for the reinstallation of the door. 

1.  Unscrew the lower hinge and take off the door. 

2.  Push the kick plate to the right in the new position. 

3.  Undo the upper hinge fastener and fix it to the opposite side of the housing, where you 

have already removed and replaced the fastener with the hole to the opposite side. 

4.  Put the door on the upper hinge fastener. 

5.  Fix the lower hinge in the new position. 

6.  Unscrew the handle and place it on the opposite side. 

7.  Some screws are covered with caps.  Take off these caps before undoing the screws. 

8.  Check the door gasket.  It should not be creased and should seal well. 

 
 
 
 
 
 

 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 

1. Upper hinge fastener  

4. Handle 

 

2. Lower hinge  

5. Door hinge fixture 

 

3. Kick plate  

6. Door hinge fixture plug 

 

Door Handle Installation: 

The door has two screw holes on each side, allowing you to install a handle (included).  To 
do so, align the handle with the screw holes on the side you prefer. Fix the handle in place 
with the included screws, then cover the screw heads with the handle seal (included). 
 

 

Models FF6, FF6L, 

FF7L, FF7LBL, 
SCR600L and 
SCR600BL 

Содержание FF6BI series

Страница 1: ...RATORS Models FF6BI series ACCUCOLD brand FF7BI series ACCUCOLD brand SCR600LBI series ACCUCOLD brand SCR600BLBI series SUMMIT Commercial M405 CM411L Instruction Manual BEFORE USE PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS FELIX STORCH INC 770 Garrison Avenue Bronx NY 10474 www summitappliance com ...

Страница 2: ...educe the risk of fire electrical shock or injury when using the appliance follow basic precautions including the following Plug into a grounded 3 prong outlet Do not remove grounding prong do not use an adapter and do not use an extension cord It is recommended that a separate circuit serving only your refrigerator be provided Use receptacles that cannot be turned off by a switch or pull chain Ne...

Страница 3: ...n to operate play with or crawl inside the refrigerator Do not use solvent based cleaning agents or abrasives on the interior These cleaners may damage or discolor the interior Do not use this apparatus for other than its intended purpose THE FF6BI AND FF7BI SERIES MODELS AS WELL AS MODEL SCR600LBI ARE DESIGNED FOR MEDICAL OR PHARMACEUTICAL USE ONLY THEY ARE NOT INTENDED FOR USE AS HOUSEHOLD REFRI...

Страница 4: ...g Your Appliance Care and Maintenance 10 Cleaning Your Appliance Power Failure Vacation Time Moving your Appliance Energy Saving Tips Troubleshooting 11 Limited Warranty 15 Location of Parts Temperature control dial thermostat and interior light Door with storage compartments Front ventilation slots kick plate Leveling legs Adjustable shelves wire for FF6 FF6L glass for FF6B Defrost water outlet b...

Страница 5: ...F7LBL Defrost water outlet NOTE Lock on models FF7LBI and FF7LBLBI is located on the front of the door near the top center Handle FF7BI series Temperature control dial thermostat light switch and interior light Glass door Front ventilation slots kick plate Leveling legs Adjustable shelves wire for SCR600LBI glass for SCR600BLBI Defrost water outlet Handle SCR600BI series Lock ...

Страница 6: ...helves and lock glass door SCR600BLBI black with glass shelves and lock glass door Capacity 5 5 cu ft Electrical Input 115V AC 60Hz Rated Current 1 0A Refrigerant R134a 1 8 oz Installation Built in or Freestanding Unit Dimensions W x D x H 23 63 x 23 5 x 33 5 NOTES 1 FF6BI and FF7BI series models and SCR600LBI are suitable for storing vaccines pharmaceuticals and other temperature sensitive materi...

Страница 7: ...rculation to cool the compressor and condenser Even when built in the unit requires at least 2 of clearance at the back 1 8 3mm at both sides and 1 16 1 6mm at the top Take care that the air vents at the front of the appliance are never covered or blocked in any way Locate the unit away from direct sunlight and sources of heat oven heater radiator etc Direct sunlight may affect the acrylic coating...

Страница 8: ...amage the power cord Extension Cord Do not use an extension cord with this appliance If the power cord is too short have a qualified electrician or service technician install an outlet near the appliance Reversing the Door Swing select models only If you find the direction of opening the door of the appliance inconvenient you can change it Holes on the opposite side have already been prepared at t...

Страница 9: ...ner 5 Fix the lower hinge in the new position 6 Unscrew the handle and place it on the opposite side 7 Some screws are covered with caps Take off these caps before undoing the screws 8 Check the door gasket It should not be creased and should seal well 1 Upper hinge fastener 4 Handle 2 Lower hinge 5 Door hinge fixture 3 Kick plate 6 Door hinge fixture plug Door Handle Installation The door has two...

Страница 10: ... the compressor NOTES 1 Shelves are adjustable Certain models include glass shelves see Technical Information page 5 These shelves stop short an inch before the back wall which is essential for air flow and the proper operation of the automatic defrost system Do not block these gaps 2 a Interior lighting on the FF6BI series models is controlled by a switch that is activated by the opening and clos...

Страница 11: ...appliance if you minimize the number of times the door is opened If the power is going to be off for a longer period of time you need to take the proper steps to protect your frozen and chilled items Vacation Time During long absences remove all contents Unplug the appliance clean it and leave the door open slightly to avoid possible formation of condensation mold or odors Moving Your Appliance 1 ...

Страница 12: ...e air circulation behind the appliance and wipe the dust from the condenser Noise Cooling in refrigeration appliances is enabled by the refrigerating system with a compressor which produces noise How noisy the appliance is depends on where it is placed how it is used and how old the appliance is During the operation of the compressor the noise of liquid is heard and when the compressor is not oper...

Страница 13: ...12 Notes ...

Страница 14: ...13 Notes ...

Страница 15: ...14 Notes ...

Страница 16: ... approved by warrantor 4 Replacement parts or repair labor costs for units operated outside the United States 5 Repairs to parts or systems resulting from unauthorized modifications made to the appliance 6 Expenses for travel and transportation for product service in remote locations 7 The removal and reinstallation of your appliance if it is installed in an inaccessible location or is not install...

Отзывы: