4
The ice maker should not be located next to ovens, grills or other sources of high
heat.
The ice maker must be installed with all electrical, water and drain connections in
accordance with state and local codes. A standard electrical supply (115 VAC
only, 60 Hz, 15 A), properly grounded in accordance with the National Electrical
Code and local codes and ordinances is required.
Do not kink or pinch the power supply cord or drain lines between the ice maker
and the cabinet.
The fuse (or circuit breaker) size should be 15 amperes.
It is important for the ice maker to be leveled in order to work properly. You may
need to make several adjustments to level it.
All installations must be in accordance with local plumbing code requirements.
Make certain that the hoses are not pinched or kinked or damaged during
installation.
Check for leaks after connection.
Never allow children to operate, play with or crawl inside the ice maker.
Although the unit has been tested at the factory, due to long-term transit and
storage, the first batch of cubes must be discarded.
Never turn the water supply tap off when the ice maker is working.
If the ice maker will not be used for a long time, before the next use it must be
thoroughly cleaned. Follow carefully any instructions provided for cleaning or use
of sanitizing solution. Do not leave any solution inside the ice maker after cleaning.
DO NOT touch the condenser fins. They are sharp and can be damaged easily.
DO NOT use solvent-based cleaning agents or abrasives on the interior. These
cleaners may transmit taste to the ice cubes, or damage or discolor the interior.
The ice machine cleaner contains acids. DO NOT use or mix with any other
solvent-based cleaner products. Use rubber gloves to protect hands. Carefully read
the material safety instructions on the container of the ice machine cleaner.
●
Do not use this apparatus for other than its intended purpose.
SAVE THESE INSTRUCTIONS
Electrical Connection
Do not, under any circumstances, cut or remove the third (ground) prong from the
power cord. For personal safety, this appliance must be properly grounded. The power
cord of this appliance is equipped with a 3-prong grounding plug that mates with a
standard 3-prong grounding wall outlet to minimize the possibility of electric shock
hazard from the appliance. Have the wall outlet and circuit checked by a qualified
electrician to make sure the outlet is properly grounded. When a standard 2-prong wall
outlet is encountered, it is your responsibility and obligation to have it replaced with a
properly grounded 3-prong wall outlet. The ice maker should always be plugged into
its own individual electrical outlet which has a voltage rating that matches the rating
label on the appliance. This provides the best performance and also prevents
overloading house wiring circuits which could cause a fire hazard from overheated
wires. Never unplug your ice maker by pulling on the power cord. Always grip the