background image

 

 

13

NOTE: The drain hose should never be allowed to hang or loop higher than the bottom 
of the ice storage bin.

 

 

3.

 

All horizontal runs of drain lines must have a fall of 

¼

” per foot. An air gap will likely 

be required between the ice maker drain hose and the drain/waste receptacle. A stand 
pipe with a trap below it would be acceptable for the drain/waste receptacle. A floor drain 
is also acceptable. 

4.

 

Pour 1 gallon of water into the ice storage bin to check for leaks at all drain connections 
and at the nut of the drain water hole. Tighten any connections or nuts that leak. 

 

Installation Types 

This ice maker has been designed for Mobile (free-standing), Enclosed (as under a cabinet) 
or Built-in (sealed) installation, indoor or outdoor. In any case, there must be adequate air 
space around the unit for proper ventilation. (See diagrams on page 8.)   

Mobile installation:

 

A mobile installation will allow you to install the ice maker free-standing in any place you 
desire provided you have access to a water supply. You must follow the stated instructions 
for 

a.

 

Electrical requirements 

b.

 

Water supply   

c.

 

Leveling the ice maker 

Enclosed Installation: 

An enclosed installation will allow you to install the ice maker under a cabinet or inside a 
kitchen cabinet provided the required clearance space around the ice maker is respected. This 
installation has the same requirements as a mobile installation.   

Built-in Installation: 

If this method of installation is chosen, it will still be necessary to allow adequate ventilation 
space around the unit. The following additional items must be observed. 

1.

 

Place ice maker in front of installation location. Remove the legs and place the unit flat 
on the floor or on a platform depending on your installation requirements. 

2.

 

The water supply line must be plumbed before connecting to the ice maker. 

3.

 

Connect the drain hose. 

4.

 

Turn on main water supply and tap. Check for water supply connection leaks. Tighten 
every connection (including connections at the water inlet). 

5.

 

If the electrical outlet for the ice maker is behind the cabinet, plug in the ice maker. 

6.

 

Push the ice maker into position. 

7.

 

Seal all around the cabinet to the floor with an approved caulking compound. 

 

 

Содержание BIM70

Страница 1: ...Automatic Ice Maker User s Manual Be sure unit is standing upright 24 hours prior to plug in Model BIM70 Felix Storch Inc 770 Garrison Avenue Bronx New York 10474 www summitappliance com...

Страница 2: ...nstallation Types 13 OPERATION 14 17 Final Check List before Operation 14 Operating Method 15 How the Machine Makes Ice 15 16 Normal Sounds 16 17 Preparing the Ice Maker for Long Storage 17 CLEANING A...

Страница 3: ...oduct damage serious personal injury or death CAUTION means that failure to heed this safety statement may result in minor or moderate personal injury or property or equipment damage All safety messag...

Страница 4: ...other appliance The fumes can create a fire hazard or explosion Before proceeding with cleaning and maintenance operations make sure the power line of the unit is disconnected and the water line is sh...

Страница 5: ...DO NOT touch the condenser fins They are sharp and can be damaged easily DO NOT use solvent based cleaning agents or abrasives on the interior These cleaners may transmit taste to the ice cubes or da...

Страница 6: ...use an extension cord with this ice maker TECHNICAL INFORMATION Model BIM70 Electrical power 115VAC 60Hz Power consumption 12 kWh 100 lbs of ice Ice making harvest rated current 6 7A 11 2A Refrigerant...

Страница 7: ...ds that this manual be kept in a place where it can be accessed when needed Every SUMMIT Ice Maker is designed and manufactured according to the highest standards of safety and performance It meets or...

Страница 8: ...7 COMPONENT LOCATIONS Door Ice cube full sensor Front cover Ventilation louvers Leveling caster Control box behind front cover Power switch Top cover Right side Water sump Ice storage bin Ice scoop...

Страница 9: ...briskly with your thumb Tape or glue residue can also be easily removed by rubbing a small amount of liquid dish soap over the adhesive with your fingers Wipe with warm water and dry Do not use sharp...

Страница 10: ...gravity drain is not available The ice maker requires a continuous water supply with a minimum pressure of 20psig and a static pressure not to exceed 80psig The temperature of the water feeding into t...

Страница 11: ...nd local codes and ordinances is required It is recommended that a separate circuit serving only your ice maker be provided Use receptacles that cannot be turned off by a switch or pull chain The fuse...

Страница 12: ...llows you to move the unit and have easy access to the surface to be cleaned IMPORTANT Once you are ready to install the ice maker in a cabinet or directly on the floor you must adjust the feet to lev...

Страница 13: ...installation requirements Drain Line IMPORTANT This ice maker is not a freezer It must connect to a drain line Your machine comes equipped with a gravity drain Depending on your plumbing setup a conde...

Страница 14: ...pply You must follow the stated instructions for a Electrical requirements b Water supply c Leveling the ice maker Enclosed Installation An enclosed installation will allow you to install the ice make...

Страница 15: ...nd 6 Has the water supply pressure been checked to ensure a minimum of 20psig with a static pressure not to exceed 80psig 7 Is there a clearance of at least 4 in 101 mm at the rear and 0 6 in 15 mm at...

Страница 16: ...ck of the machine and empty into the floor drain IMPORTANT Although the unit has been tested at the factory due to long term transit and storage the first batch of cubes must be discarded Never turn t...

Страница 17: ...r sump Gradually during the freezing portion of the ice making cycle the water in the sump will become highly concentrated with mineral impurities During the harvest cycle fresh water flows into the m...

Страница 18: ...the ice maker will not be used for a long time or is to be moved to another place it will be necessary to drain the system of water Shut off the water supply at the main water source Disconnect the wa...

Страница 19: ...ons You may want to shorten the intervals if you have pets or the unit is used outdoors or there are other special considerations What shouldn t be done Never keep anything in the ice storage bin that...

Страница 20: ...is normal Condenser Cleaning 1 A dirty or clogged condenser prevents proper airflow reduces ice making capacity and causes higher than recommended operating temperatures that may lead to component fai...

Страница 21: ...and 2 gallons of warm water 95 to 115 F 3 Rinse thoroughly with clear water The waste water will be drained off through the drainpipe 4 Reconnect power to the unit The ice scoop should be washed regul...

Страница 22: ...ing solution can be prepared in a plastic basin with Nu Calgon Nickel Safe Ice Machine Cleaner Mix 4 ounces of the ice machine cleaner per gallon of warm water Remove the sprinkler arm from the interi...

Страница 23: ...o 20 grains gal 4 to 5 grains liter you may need to clean the system as often as every 6 months 1 Turn off power to the ice maker Keep the ice maker connected to the water supply and drainpipe 2 Open...

Страница 24: ...em 3 times NOTE The use of the Ice Maker Cleaner Solution in the water sump during the rinse is not needed 7 Prepare a sanitizing solution made of 1 ounce of household bleach and 2 gallons of warm wat...

Страница 25: ...en this LED is lit the unit is working in the Ice Making mode controlled by a temperature probe on the evaporator When the green LED is flashing the unit is working in the Ice Making mode controlled b...

Страница 26: ...ice cubes The Ice Full LED red will flash as you lower the ice size and will finally be blinking at the setting of smallest ice size Larger ice setting By pressing the Mode button you can increase th...

Страница 27: ...icate various work modes 4 Indication of failure of major control box fuse 5 The fan motor responds to the ambient temperature If it is cold the motor will stop working to keep the cooling system in g...

Страница 28: ...be malfunctioning read through the Operation section of this manual first If the problem persists check the Troubleshooting Guide below and on the following page The problem could be something very si...

Страница 29: ...28...

Страница 30: ...ts or components including but not limited to cabinet paint finish temperature control refrigerant metering device driers motor starting equipment fan assembly or any other electrical component etc WA...

Страница 31: ...d compressor warranty specifically described above These warranties are exclusive and in lieu of all other warranties including implied warranty and merchantability or fitness for a particular purpose...

Страница 32: ...31 Tested and certified to NSF standard 12 by NSF International Probado y certificado por NSF International de acuerdo con la norma NSF 12 Printed in China BIM70 0M 072412...