![SUMMIT EQUIPMENT SC-3248 Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/summit-equipment/sc-3248/sc-3248_safety-operation-and-maintenance-manual_1392045022.webp)
(Routine Preventative Maintenance, continued)
D.
D.
D.
D. General care:
General care:
General care:
General care: If the answer to any general care question
is confirmed as “No,” shut down and lock out the power to
the compactor (see page 3.8 above) and do not return the
compactor to service until all issues are resolved.
YES/NO
Is the area around the compactor clean and
reasonably free of obstructions and debris,
providing safe access for operating personnel?
When the compactor operates, is it free of any
unusual operation or noise?
Does the sight glass or dipstick indicate
sufficient hydraulic fluid in the reservoir when
the compactor platen is fully retracted?
Does a visual inspection reveal that all hoses,
covers, chutes, hoppers, doors, push-buttons,
and other compactor parts are in good
condition?
Does a visual inspection by a qualified
electrician or technician inside electrical
enclosures reveal that all components are
secured and free from indications of
overheating or loose or frayed wires?
Are the contacts, arms, or rollers on limit
switches straight and operating as they should
be, and not bent or fouled?
Are the platen guide wear shoes supporting the
platen without signs of wear and looseness
such that they should be replaced?
3.9
PO Box 1847, Post Falls, ID 83877-1847 • T (208) 773-3885 • F 773-3799 • E <[email protected]>