25
Control panel:
Description of LEDs and buttons:
1.
Bin Full (Red) LED
:
Bin full indicator light
When this is lit, the ice storage bin is full of ice or there is something blocking the
bin-full probe. The unit will stop working. When ice cubes are removed from the ice
storage bin, freeing the bin-full probe, the red LED will remain flashing for 3 minutes,
then the unit will restart and return to the ice making mode.
2.
Ice Making (Green) LED
:
Ice making indicator light
When this is lit, the unit is working in the ice making mode controlled by a
temperature probe on the evaporator. When the green LED flashes, the unit is working
in the ice making mode controlled by a fixed timer.
3.
Ice Harvest (Yellow) LED
: Ice harvest indicator light
When this is lit, the unit is working in the ice harvest mode controlled by the ice-full
probe.
4.
Mode button
: Mainly for service. When this is pressed, the ice making mode changes
to the ice harvest mode or vice versa. The mode can be judged from the status of the
green and yellow LEDs.
5.
Adjust button
: Mainly for service. When this is pressed over 3 seconds, the unit will
enter the Ice Size Adjustment mode. The mode can be judged from the status of the
yellow LED.
Ice Size Adjustment Guide:
1.
Press and hold the “
Adjust
” button for at least 3 seconds. The unit will enter the Ice
Size Adjustment mode. The “
HARVEST
” LED (yellow) will be blinking continuously
during the ice size adjustment. Release the button when the LED blinks continuously
to adjust the ice size.
+
_
Содержание BIM-44 G
Страница 58: ...57 Notes Notas...