background image

 

Installation Instructions 

 

Before Using Your Appliance: 

 

Remove the exterior and interior packing. 

 

Before connecting the unit to a power source, let it stand for approximately 2 
hours. This will reduce the possibility of a malfunction in the cooling system from 
handling during transportation. 

 

Remove the shelves and clean them and the interior surfaces of the unit with 
lukewarm water using a soft cloth. 

 

Installing the Refrigerator: 

 

Place the unit on a floor that is strong enough to support it when the appliance is 
fully loaded. To level the unit, adjust the two leveling legs at the front. 

 

Your appliance can be installed either free-standing, recessed or built into an 
enclosure. When installing as a free-standing unit, allow at least 2” (51mm) of 
space at the sides, top and rear of the unit to allow for proper air circulation to cool 
the compressor and condenser. Even when built in, the unit requires at least 2” of 
clearance at the back, 1/8” (3mm) at both sides and 1/16” (1.6mm) at the top. 
Take care that the air vents at the front of the appliance are never covered or 
blocked in any way. 

 

This appliance is supplied with spacers that have to be mounted onto the 
condenser tube at the back to make sure there is sufficient clearance between the 
appliance and the wall. 
 

 

 

 

Locate the unit away from direct sunlight and sources of heat (oven, heater, 
radiator, etc.). Direct sunlight may affect the acrylic coating and heat sources may 
increase electrical consumption. Extremely cold ambient temperatures may also 
affect the unit's performance. 

 

Avoid locating the unit in moist areas. Too much moisture in the air will cause frost 
to form quickly on the evaporator, requiring more frequent defrosting of the 
interior. 

 

Plug the unit into an exclusive, properly installed and grounded wall outlet. Any 
questions concerning power and/or grounding should be directed toward a 
certified electrician or authorized service center. 

 
 
 
 
 

Содержание FF61BI

Страница 1: ...l No ______________________ BUILT IN AUTO DEFROST ALL REFRIGERATORS Models M405 CM411L Instruction Manual BEFORE USE PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS FELIX STORCH INC 770 Garrison Avenue Bronx NY10474 www summitappliance com CFF61BI FF63BBI ...

Страница 2: ...r or replace any part of your refrigerator unless it is specifically recommended in this material All other servicing should be referred to a qualified technician Use two or more people to move and install the refrigerator Failure to do so can result in back or other injury To ensure proper ventilation for your appliance the front of the unit must be completely unobstructed Choose a well ventilate...

Страница 3: ...S THEY HAVE BEEN ADEQUATELY SUPERVISED BY A RESPONSIBLE PERSON TO ENSURE THAT THEY CAN USE THE APPLIANCE SAFELY YOUNG CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT THEY DO NOT PLAY WITH THE APPLIANCE SAVE THESE INSTRUCTIONS To save energy and maintain optimum performance Your refrigerator may be installed as a free standing unit or built into an enclosure or below a countertop When positioning this...

Страница 4: ...ing Your Refrigerator 8 Temperature Control Defrosting Your Appliance Care and Maintenance 9 Cleaning Your Appliance Power Failure Vacation Time Moving your Appliance Energy Saving Tips Troubleshooting 10 Limited Warranty 11 Location of Parts Temperature control dial thermostat and interior light Door with storage compartments Front ventilation slots kick plate Leveling legs Adjustable glass shelv...

Страница 5: ... exterior Capacity 5 5 cu ft Electrical Input 115V AC 60Hz Rated Current 0 902A Refrigerant R134a 1 7 oz Unit Weight 86 lbs Installation Built in or free standing Unit Dimensions W x D x H 23 63 x 23 5 x 33 5 NOTE Specifications are subject to change without notice ...

Страница 6: ...nd condenser Even when built in the unit requires at least 2 of clearance at the back 1 8 3mm at both sides and 1 16 1 6mm at the top Take care that the air vents at the front of the appliance are never covered or blocked in any way This appliance is supplied with spacers that have to be mounted onto the condenser tube at the back to make sure there is sufficient clearance between the appliance an...

Страница 7: ...tlet is encountered it is your responsibility and obligation to have it replaced with a grounded 3 prong wall outlet To prevent accidental injury the cord should be secured behind the unit and not left exposed or dangling The unit should always be plugged into its own individual electrical outlet which has a voltage rating that matches the rating label on the appliance This provides the best perfo...

Страница 8: ...4 Remove the screws to the bottom hinge 5 Remove the decorative caps from the opposite side and plug the holes from the original side with the decorative caps 6 Move the bottom hinge to the opposite side and tighten the screws Use any lock washers or nuts if they were used in the original installation 7 Replace door onto the hinge pin on the bottom hinge Place top hinge pin into door Insert screws...

Страница 9: ...ar Place contents accordingly It is best not to operate these units mostly empty If temperatures are erratic try putting some water bottles inside to create a load for the compressor NOTES 1 The glass shelves are adjustable These shelves stop short an inch before the back wall which is essential for air flow and the proper operation of the automatic defrost system Do not block these gaps 2 Interio...

Страница 10: ...ure of your appliance if you minimize the number of times the door is opened If the power is going to be off for a longer period of time you need to take the proper steps to protect your chilled items Vacation Time During long absences remove all contents Unplug the appliance clean it and leave the door open slightly to avoid possible formation of condensation mold or odors Moving Your Appliance 1...

Страница 11: ...rculation behind and in front of the appliance and wipe the dust from the condenser Noise Cooling in refrigeration appliances is enabled by the refrigerating system with a compressor which produces noise How noisy the appliance is depends on where it is placed how it is used and how old the appliance is During the operation of the compressor the noise of liquid is heard and when the compressor is ...

Страница 12: ... not approved by warrantor 4 Replacement parts or repair labor costs for units operated outside the United States 5 Repairs to parts or systems resulting from unauthorized modifications made to the appliance 6 Expenses for travel and transportation for product service in remote locations 7 The removal and reinstallation of your appliance if it is installed in an inaccessible location or is not ins...

Отзывы: