background image

2

TROUBLESHOOTING

You can solve many common problems easily, saving you the cost of a possible service call. Try the 

suggestions below to see if you can solve the problem before calling the servicer.

PROBLEM

SOLUTION

Kegerator does not 

operate

Not plugged in or the appliance is turned off.

The circuit breaker tripped or a fuse has blown out. 

Kegerator is not cold 

enough

Check the temperature control setting. 

External environment may require a higher setting. 

The door is opened too often. 

The door is not closed completely. 

The door gasket is not sealing properly. 

Kegerator is turning on 

and off frequently 

The room temperature is hotter than normal. 

The door is opened too often. 

The door is not closed completely. 

The temperature control is not set correctly. 

The door gasket does not seal properly. 

The light does not work

Not plugged in. 

The circuit breaker tripped or a fuse has blown. 

The light bulb has burned out. 

The light button is “OFF”

PROBLEM

SOLUTION

Vibrations

Check to assure that the kegerator is on a level surface. 

The kegerator seems to 

make too much noise. 

A faint humming noise may come from the flow of the 

refrigerant, which is normal. 

As each cycle ends, you may hear gurgling sounds 

caused by the flow of the refirgerant in your kegerator. 

Contraction and expansion of the inside walls may 

cause popping and crackling noises. 

During the defrosting process you may hear a water 

flowing sound cuased by water flowing through the 

drain trough. 

The kegerator is not on a level surface. 

The door will not close 

properly 

The kegerator is not on a level surface. 

The gasket is dirty.

The shelves are out of position. 

Smell/Odor 

Check for leaks on inside surface or around the keg 

coupler.

Outer surface of 

appliance is wet

Condensation has formed and can be wiped dry. 

External surface is warm

Compressor is working to transfer heat from inside 

the cabinet. 

Remove the exterior and interior packaging, 

but do not remove any foam insulation

surrounding the pipes at the back. 

Before connecting the unit to the power

source, let it stand for approximately 24

hours. This will reduce the possibility of

malfunction in the cooling system from

handling during transportation. 

Clean the interior surface with lukewarm

water using a soft cloth. 

Place the unit on a flat, solid floor that is

strong enough to support it when it is fully

loaded. To level the appliance, adjust the

rolling casters at the bottom of the unit. 

When moving your kegerator, please do not 

incline it more than 45 degrees. 

Locate the appliance away from direct

sunlight and sources of heat (stove, heater,

1. 

Position the unit on a flat, level surface

capable of supporting the entire weight 

of the unit. Remember the unit will be 

significantly heavier once it is fully loaded. 

2. 

Connect the unit to a Ground Fault

Interrupter (GFI). 

3.

The unit must be installed according to your 

local codes and ordinances. 

4.

ELECTROCUTION HAZARD!

• Electrical Grounding Required - This

appliance is equipped with a three

prong (grounding) polarized plug for

your protection against possible shock

hazards. 

• NEVER remove the round grounding

prong from the plug. 

• NEVER use a two prong grounding

adapter.

BEFORE USE:

radiator, etc.). Direct sunlight may affect 

the acrylic coating and heat sources may 

increase electrical consumption. Extreme 

cold ambient temperatures may also 

cause the unit to perform improperly. The 

optimal ambient temperature range is 50°F 

- 109.4°F. Do not mount the draft tower

remotely, as the exposed beer line will not

be refrigerated, causing foam. 

Avoid locating the unit in damp areas.

Unwind the power cord to its full length and 

inspect for damage before plugging into

the outlet. 

Plug the kegerator into an exclusive,

properly installed and grounded wall outlet. 

Do not under any circumstances cut or

remove the third (ground) prong from

the power cord. Any questions concerning

power and/or electrical grounding should

be directed to a certified electrician or

authorized products service center. 

After plugging the appliance into a wall

outlet, allow the unit to cool down for 3

to 4 hours before installing a keg in the

appliance. 

It is recommended that you install the appliance 

in a place where the ambient temperature 

is between 50°F and 109.4°F (10°C-43°C). If 

the ambient temperature is above or below 

recommended temperatures, the performance 

of the unit may be affected. For example, placing 

your unit in extremely cold or hot conditions 

may cause interior temperatures to fluctuate. 

The operating temperature range may not be 

reached. 

Содержание SSRFR-24DK

Страница 1: ...KEGERATORS ...

Страница 2: ......

Страница 3: ...r years to come As a family business with over 30 years of industry experience we aim to deliver exceptional quality and personal service Welcome to the Summerset family and we hope you love your new kegerator INSTALLER Please leave this manual for the owner Serial Number Model Date of Purchase Place of Purchase To view on your phone scan the QR code on your smart phone s camera app For Android de...

Страница 4: ...cing Failure to do so can result in electrical shock or death Do not attempt to repair or replace any part or your appliance unless it is specifically recommended in this manual All other servicing should be referred to a qualified technician WARNING Most power failures are corrected within a few hours and should not affect temperature of your appliance if you minimize the number of times the draw...

Страница 5: ...be located next to ovens grills or other sources of high heat The appliance must be installed with all electrical water and drain connections in accordance with state and local codes A standard electrical supply 115 V AC only 60HZ properly grounded in accordance with the National Electrical Code and local codes and ordinances is required Do not kink or pinch the power supply cord of the appliance ...

Страница 6: ......

Страница 7: ...TABLE OF CONTENTS Before Operating Troubleshooting Operating Your Appliance Installation Warranty 1 2 3 4 6 ...

Страница 8: ...cumulate on the evaporator if the unit is repeatedly opened in a high heat or high humidity location If this frost pattern does An audible alarm sounds if the storage temperature is not cold enough The temperature display flashes at the same time The cause of the temperature being too high may be Too much warm ambient air flowed in when rearranging and removing stored items Power failure for some ...

Страница 9: ...andling during transportation Clean the interior surface with lukewarm water using a soft cloth Place the unit on a flat solid floor that is strong enough to support it when it is fully loaded To level the appliance adjust the rolling casters at the bottom of the unit When moving your kegerator please do not incline it more than 45 degrees Locate the appliance away from direct sunlight and sources...

Страница 10: ...10 43 degrees Celsius If the ambient temperature is above or below this range the performance of the unit may be affected For example placing your unit in extreme cold or hot conditions may cause interior temperatures to fluctuate Please be aware that the desired temperatures may fluctuate depending on the ambient temperature and the orientation of the keg Press first then press or button to incre...

Страница 11: ...ide it through both openings If mounting to a counter top secure your tower using the four long bolts nuts and 2 rubber washers If mounting directly onto your kegerator use the 4 short bolts and metal washers INSTALLATION Unpackage your kegerator and lay out the kegerator parts on a flat surface ensuring you have the following STEP 1 STEP 2 5 Keg Tower w Hose 6 Red Hose w 2 Fasteners 7 4 Short Bol...

Страница 12: ...rd always grip the plug firmly and pull straight out from the receptacle Repair or replace immediately all power cords that have become frayed or otherwise damaged Do not use a cord that shows cracks or abrasion damage along its length or at either end When moving the appliance be careful not to damage the power cord Because of potential safety hazards under certain conditions it is strongly recom...

Страница 13: ...turer shall not be liable for incidental consequential special or contingent damages resulting from its breach SUMMERSET REFRIGERATION WARRANTY WARRANTY SERVICE REPLACEMENT PARTS Call your authorized selling dealer or call Summerset directly at 800 966 8126 Be prepared to furnish the following information Purchaser s name model and serial number of the Power burner date of purchase and the accurat...

Страница 14: ... every outdoor living expression We offer a wide range of products from grills refrigeration sinks accessories and more Our goal is to ensure you have everything you need to create your perfect outdoor atmosphere No matter the style or budget Summerset will deliver an experience that will help create the ultimate backyard getaway We are a family owned and operated business that is located in beaut...

Отзывы:

Похожие инструкции для SSRFR-24DK