background image

5

This appliance should be properly grounded for 

your safety. The power cord of this appliance is 

equipped with a three-prong plug which mates 

with a standard three-prong wall outlet to 

minimize the possibility of electrical shock. 

Do not under any circumstance cut or remove 

the third (ground) prong from the power cord 

supplied. For personal safety, this appliance must 

be properly grounded. Any questions concerning 

power and/or grounding should be directed 

toward a certified electrician or an authorized 

service center. 

The appliance requires a standard 115/220 Volt 

AC-60HZ three-prong grounded electrical outlet. 

Have the wall outlet and circuit checked by a 

qualified electrician to make sure they outlet is 

properly grounded. When a standard 2-prong 

wall outlet is encountered, it is your responsibility 

and obligation to have it replaced with a properly 

grounded 3-prong wall outlet. 

To prevent accidental injury, the cord should 

be secured behind the appliance and not left 

exposed dangling.

The appliance should always be plugged into 

its own individual electrical outlet which has a 

voltage rating that matches the rating label on 

the appliance. This provides the best performance 

and also prevents overloading house wiring 

circuits that could cause a fire hazard from over 

heating. Never unplug the appliance by puling 

on the power cord, always grip the plug firmly 

and pull straight out from the receptacle. Repair 

or replace immediately all power cords that have 

become frayed or otherwise damaged. Do not 

use a cord that shows cracks or abrasion damage 

along its length or at either end. When moving 

the appliance, be careful not to damage the 

power cord. 

Because of potential safety hazards under certain 

conditions, it is strongly recommended that you 

do not use an extension cord with this appliance. 

However, if you must use an extension cord it is 

absolutely necessary that it be a UL/CUL-Listed, 

3-wire grounding type appliance extension cord

having a ground type plug and outlet and that

the electrical rating of the cord be 115 volts and at 

least 1.3 amperes. 

ELECTRICAL CONNECTION CONTINUED

EXTENSION CORD

INSTALLATION

This appliance includes a stainless-steel handle 

that is not required to operate this unit. To install 

the handle please follow the below instructions:

1. 

Pull away the door gasket in the area where 

the handle is to be installed as shown in

illustration. The gasket is easily displaced by 

hand, no tools are necessary. 

2. 

Locate the screws included in the bag with

the user’s guide. Insert the screws into the

holes as shown. 

3.

Align the handle with the screws installed.

Tighten the screws using a Phillips head

screwdriver until the handle sets both flush 

and secured tightly against the door frame. 

(DO NOT over tighten as this will cause

damage to the handle assembly).

4.

Replace the door gasket to its original

Position. 

INSTALLING THE STAINLESS STEEL HANDLE

Содержание SSRFR-24DK

Страница 1: ...KEGERATORS ...

Страница 2: ......

Страница 3: ...r years to come As a family business with over 30 years of industry experience we aim to deliver exceptional quality and personal service Welcome to the Summerset family and we hope you love your new kegerator INSTALLER Please leave this manual for the owner Serial Number Model Date of Purchase Place of Purchase To view on your phone scan the QR code on your smart phone s camera app For Android de...

Страница 4: ...cing Failure to do so can result in electrical shock or death Do not attempt to repair or replace any part or your appliance unless it is specifically recommended in this manual All other servicing should be referred to a qualified technician WARNING Most power failures are corrected within a few hours and should not affect temperature of your appliance if you minimize the number of times the draw...

Страница 5: ...be located next to ovens grills or other sources of high heat The appliance must be installed with all electrical water and drain connections in accordance with state and local codes A standard electrical supply 115 V AC only 60HZ properly grounded in accordance with the National Electrical Code and local codes and ordinances is required Do not kink or pinch the power supply cord of the appliance ...

Страница 6: ......

Страница 7: ...TABLE OF CONTENTS Before Operating Troubleshooting Operating Your Appliance Installation Warranty 1 2 3 4 6 ...

Страница 8: ...cumulate on the evaporator if the unit is repeatedly opened in a high heat or high humidity location If this frost pattern does An audible alarm sounds if the storage temperature is not cold enough The temperature display flashes at the same time The cause of the temperature being too high may be Too much warm ambient air flowed in when rearranging and removing stored items Power failure for some ...

Страница 9: ...andling during transportation Clean the interior surface with lukewarm water using a soft cloth Place the unit on a flat solid floor that is strong enough to support it when it is fully loaded To level the appliance adjust the rolling casters at the bottom of the unit When moving your kegerator please do not incline it more than 45 degrees Locate the appliance away from direct sunlight and sources...

Страница 10: ...10 43 degrees Celsius If the ambient temperature is above or below this range the performance of the unit may be affected For example placing your unit in extreme cold or hot conditions may cause interior temperatures to fluctuate Please be aware that the desired temperatures may fluctuate depending on the ambient temperature and the orientation of the keg Press first then press or button to incre...

Страница 11: ...ide it through both openings If mounting to a counter top secure your tower using the four long bolts nuts and 2 rubber washers If mounting directly onto your kegerator use the 4 short bolts and metal washers INSTALLATION Unpackage your kegerator and lay out the kegerator parts on a flat surface ensuring you have the following STEP 1 STEP 2 5 Keg Tower w Hose 6 Red Hose w 2 Fasteners 7 4 Short Bol...

Страница 12: ...rd always grip the plug firmly and pull straight out from the receptacle Repair or replace immediately all power cords that have become frayed or otherwise damaged Do not use a cord that shows cracks or abrasion damage along its length or at either end When moving the appliance be careful not to damage the power cord Because of potential safety hazards under certain conditions it is strongly recom...

Страница 13: ...turer shall not be liable for incidental consequential special or contingent damages resulting from its breach SUMMERSET REFRIGERATION WARRANTY WARRANTY SERVICE REPLACEMENT PARTS Call your authorized selling dealer or call Summerset directly at 800 966 8126 Be prepared to furnish the following information Purchaser s name model and serial number of the Power burner date of purchase and the accurat...

Страница 14: ... every outdoor living expression We offer a wide range of products from grills refrigeration sinks accessories and more Our goal is to ensure you have everything you need to create your perfect outdoor atmosphere No matter the style or budget Summerset will deliver an experience that will help create the ultimate backyard getaway We are a family owned and operated business that is located in beaut...

Отзывы: