11
Safety and Installation Instructions
For Liquid Propane Gas Units
The regulator supplied by the manufacturer must be used in the installation.
Attach regulator hose to the pipe connection at the rear of the unit. Tighten with a wrench but do
not over-tighten.
Install the LP tank. Make sure the tank is securely positioned in an upright position and will not fall
over. Do not operate the unit unless the tank is in an upright position.
Leak check all connections using the soapy water solution test detailed in the manual.
To connect, insert the regulator inlet to the tank valve and turn the black coupler clockwise until the
coupler tightens securely. Do not over-tighten the coupler connection.
To disconnect, turn the tank valve OFF, hold the coupler sleeve and turn it counterclockwise.
Upon completion of assembly, turn the tank valve on and turn the control valves on the grill to the HIGH
position for 10 to 15 seconds to purge the line of air and fill the line with gas.
CAUTION
: When the grill is not in use, disconnect
and protect all fuel fittings
.
Cooking Component Installation:
Important:
Prior to first use, clean and rinse all removable components.