13
g. Running status checking
1) Press”
” for 5 seconds, a sound of “di” can be heard and it will enter into running status checking”
2) at this time, the display alternately shows status point “C0” and its corresponding value.
3) Change status pointer through”
” and “
”, the corresponding value also changes with it.
4) Press “
” can quit “running status checking” mode
5) Running status checking table
Symbol
Content
Unit
C0
Inlet water temp
℃
C1
Outlet water temp
℃
C2
Ambient temp
℃
C3
Exhaust temp
℃
C4
Outer coil pipe temp
℃
C5
Gas return temp
℃
C6
Inner coil pipe tem
℃
C9
Radiator temp
℃
C10
Electronic expansion valve opening
P
F. Testing
1. Inspect heat pump before use
a.
The ventilating device and outlets are operating adequately and are not obstructed.
b.
It’s prohibited to install refrigeration pipe or components in corrosive
environment.
c.
Inspect the electric wiring on basis of the electric wiring diagram and earthing connection.
d.
Double confirm the main machine power switch should be off.
e.
Inspect the temperature setting.
f.
Inspect the air inlet and outlet.
2. Leakage detection notice and method
a.
Leakage checking is prohibited in closed area.
b.
The ignition source is prohibited during the leakage inspection. A halide torch (or any
other detector using a naked flame) shall not be used.
c.
Leakage detection fluids can be applied with most refrigerants but the use of detergents containing chlorine
shall be avoided as chlorine may react with the refrigerant and corrode the copper pipe.
d.
Vacuumize completely before welding. Welding can only be carried out by professional personnel in service
center.
e.
Please stop using while gas leakage occur, and contact professional personnel in service center.
Содержание 108023
Страница 1: ...STYLE SILENCE INVERTER ZWEMBAD WARMTEPOMP HANDLEIDING ...
Страница 31: ...STYLE SILENCE INVERTER SCHWIMMBADWÄRMEPUMPE BENUTZERHANDBUCH ...
Страница 60: ...NOTICE D UTILISATION STYLE SILENCE POMPE A CHALEUR INVERTER POUR PISCINE ...
Страница 90: ...STYLE SILENCE INVERTER POOL HEAT PUMP MANUAL ...
Страница 114: ...23 Create Family Please set family name and choose location of device b Register through third party application ...
Страница 120: ...29 ...