Should the machine be stored or left stationary for any length of time it is recommended that the
cutter stack is re-sprayed with anti-rust lubricant and that the shafts are rotated for 1-5 minutes
every 3 months either by hand or applying power to the drive motor. Check for grinder drive
lubricant leakage. Contact Sulzer is leakage exceed 6ml.
Failure to do the above may cause the machine to seize due to the tight running clearances of the
individual cutting elements during commissioning and initial start-up.
Prior to installation/commissioning:
Check external hardware as gasketed areas may have a tendency to loosen fasteners.
Retighten if loose (refer to Torque settings).
Check paint for any slight damage and touch up if necessary. Standard Sulzer colour (RAL
5002).