Installation and Operating Instructions
40002 Inline and Channel Series
40002_Inline_and_Channel_Series_EN_20201208_V01.docx
7
Noise levels
The sound pressure level will not exceed 70 dB at one metre distance from the grinder. This is
based on a typical installation and does not necessarily include noise from other sources or any
contribution from building reverberation.
Lubrication
At 10,000 hr intervals, bearings, gears and seal assembly inspection should take place along with
gear grease replenishment.
Under tropical or other arduous conditions, however, more frequent lubrication may be necessary. It
is therefore advisable to establish a suitable maintenance schedule or periodic inspection to match
service conditions.
Handling
During installation and maintenance, attention must be paid to the safe handling of all
items. Where a grinder or its components weigh in excess of 20 kg (45 lb) it is
recommended that suitable lifting tackle should be used to ensure that personal injury or
damage to components does not occur.
Do not attempt to lift the grinder using only one lifting point. Extreme caution should be
observed for personnel safety when lifting heavy objects.
By design the cutters have sharp edges. Great care must be taken when handling. The
use of protective gloves is recommended.
Use of items not approved or manufactured by Sulzer
The grinder and its components have been designed to ensure that the grinder will operate safely
within the guidelines covered by legislation. As a consequence, Sulzer has declared the machine
safe to use for the duty specified as defined by the Declaration of Conformity and the Intended Use
that is issued with this instruction manual.
The use of replacement items that are not approved by or manufactured by Sulzer may affect the
safe operation of the grinder and it may therefore become a safety hazard to both operators and
other equipment. In these instances, the declaration provided will therefore become invalid. The
guarantee referenced in the Terms and Conditions of Sale will also be invalidated if replacement
items are used that are not approved or manufactured by Sulzer.
Inspection / Storage
Report container damage to the carrier and Sulzer.
Contact Sulzer or representative for missing, loose, or damaged parts.
All equipment should be stored in a controlled dry environment to prevent corrosion or damage to
components.
Grinders are dispatched from our factory with the cutter chamber sprayed with a moisture repellent
coating and ready for immediate installation and operation.