5 of 10
Instruction handbook DP2X
Version 1.0 · 8.10.19
EN
• Use of cartridges or spare parts of a different man-
ufacturer without written consent of the manufac-
turer
WARNING Risk of injury and acci-
dents arising from use that is not in
accordance with its intended purpose
The manufacturer is not liable for damage resulting
from non-observance of the intended purpose
3) SCOPE OF DELIVERY
Refer to figure
{C}
on page II:
4) PRODUCT OVERVIEW
Refer to the figures
{A}
to
{I}
on page II:
Safety instructions stickers
Variants / type designations
The versions of the DP dispenser are listed in the table
below:
5) FUNCTIONAL DESCRIPTION
Refer to the figures
{A}
to
{I}
on page II:
The air pressure in the pneumatic circuit is lowered by
the pressure regulation valve (8). Air Pressure drives a
cylinder piston which moves the mounted plungers (2)
into the cartridge tubes and forces material into the
static mixer.
6) PREPARING THE DISPENSER
FOR USE
Procedure
Refer to the figure
{A}
on page II:
1.
Install desired ¼" NPTF or BSPPF quick-release
coupling (not included) using two wrenches to
tighten.
2.
Connect dispenser to compressed air line and verify
connection for air leaks. May need to tighten
connection if leaks are discovered.
0
Dispenser (fitted with cartridge holder & plungers)
13 Instruction handbook
1 Cartridge guide
2 Plunger discs*
3 Dispense volume indicator
4 Pneumatic drive unit
5 Cartridge ejector button
6 Cartridge holder*
7 Trigger
8 Pressure regulation valve
9 Handle
10 Retract Button
11 Retaining Nut
12 Nose Plug
13 Instruction handbook
14 Compressed air connection
*
available as a spare part
Type
Cylinder Ø
Cartridge
volume
Ratios
DP2X-200
70 mm
200 ml
1:1 / 2:1 /
4:1 / 10:1
DP2X-400
100 mm
400 ml
_DP2X-200-400.book Seite 5 Dienstag, 8. Oktober 2019 3:18 15