4
Installation and Operating Instructions
Grinder – 10000 Open Channel Series
SULZER CONFIDENTIAL
All electrical equipment, including control and safety devices, should be suitably rated
for the environment in to which they are installed
To minimise the risk of sparking or temperature rises due to mechanical or electrical
overload the following control and safety devices should be fitted. The control system
will shut the grinder down if the motor current or temperature exceed specified limits or
a jam of the cutter stack occurs. This includes a system that reverses the machine in
order to clear any such jam. An isolator switch will disconnect all electrical supply to the
motor and ancillary electrical equipment and is capable of being locked in the OFF
position. All control and safety devices must be fitted, operated and maintained in
accordance with the manufacturer’s instructions.
The grinder must rotate in the correct direction for proper operation. This must be
checked on installation and commissioning and after any maintenance has been carried
out. Failure to observe this may lead to mechanical or electrical overload.