USER MANUAL
Models SD-820 to SD-1710 with DDS
Rev 04 – October 2005
18
Desiccant may contain pollutants.
Desiccant is to be disposed of in accordance with local, state and
federal regulations.
Replace the desiccant drain port and fill with new desiccant from the fill port
above
Start the dryer in accordance with paragraph 3.3 for initial start-up.
4.4 CHANGING THE PURGE REGENERATION ORIFICE
Depressurize the dryer and switch DRYER OFF
The regeneration orifice is integrated into pipe fittings that are threaded directly
into the top manifold
Unscrew the orifice fittings
Remove regeneration orifice and re-install new orifice as required
Verify that all pipe connections are properly secured.
NOTE: Consult Sullair for recommendations and/or replacement of the purge
regeneration orifice. Modification of the regeneration orifice can lead to
performance deterioration of the dryer.