Section 6
MAINTENANCE
39
TROUBLESHOOTING
SYMPTOM
PROBABLE CAUSE
REMEDY
COMPRESSOR WILL NOT START
Main Disconnect Switch Open
Close switch.
Line Fuse Blown
Replace fuse.
Control Transformer Fuse Blown
Replace fuse.
Motor Starter Overloads Tripped
Reset. Should trouble persist, check
whether motor starter contacts are
functioning properly.
Low Incoming Line Voltage
Check voltage. Should voltage check low,
consult power company.
Supervisor Panel Fuse is Blown
Replace fuse.
Replace Supervisor controller if no display
or erratic display.
COMPRESSOR SHUTS DOWN
WITH AIR DEMAND PRESENT
Loss of Control Voltage
Reset. If trouble persists, check that line
pressure does not exceed maximum
operating pressure of the compressor
(specified on nameplate).
Low Incoming Voltage
Consult power company. The Sullair
Supervisor will provide indication of most
maintenance problems if control power has
not been lost. Shutdowns will occur upon a
faulty condition or a bad sender condition.
Excessive Operating Pressure
Check maximum P2 pressure setting.
“High Press P1” display; Max P1 pressure
may be set too low. Consult factory for
recalibration.
Defective solenoid valve; solenoid valve
should cause control lever to move to
unload stop when the pressure switch
contacts open. Repair if defective.
Defective blowdown valve; blowdown valve
should exhaust sump pressure to 40 to 50
psig (2.8 bar to 3.4 bar) when maximum
operating pressure is reached. Repair if
defective.
Open or shorted P1, P2, P3 or P4 sender
message; replace sender indicated.
“High Temp T1“ or “T3” Message
Cooling water temperature too high;
Displayed
increase water flow (water---cooled only).
Cooling water flow insufficient; check water
lines and valves (water---cooled only).
Cooler plugged; clean tubes. If plugging
persists, install water conditioner
(water---cooled only).
Cooling air flow restricted; clean cooler and
check for proper ventilation.
Ambient temperature is too high; provide
sufficient ventilation.
Low fluid level; add fluid.
Clogged filter; change the fluid filter
element as indicated by Supervisor control.
Thermal valve not functioning properly;
replace element (air---cooled only).
Water flow regulating valve not functioning
properly; change (water---cooled only).
Open or shorted T1 or T2 sender; check for
a short or open circuit to probe and
correct wiring.
Содержание LS-25S
Страница 12: ...Section 2 DESCRIPTION 7 Figure 2 3 Compressor Piping and nstrument Diagram...
Страница 16: ...Section 2 DESCRIPTION 11 Figure 2 5A Control System Diagram Start Full Load...
Страница 17: ...Section 2 DESCRIPTION 12 Figure 2 5B Control System Diagram Modulation Unload...
Страница 47: ...Section 7 ILLUSTRATIONS AND PARTS LIST 42 7 3 MOTOR COMPRESSOR FRAME AND PARTS 150 KW 187 261 KW...
Страница 49: ...Section 7 ILLUSTRATIONS AND PARTS LIST 44 7 4 COMPRESSOR AIR INTAKE SYSTEM...
Страница 51: ...Section 7 ILLUSTRATIONS AND PARTS LIST 46 7 5 FLUID COOLING PIPING SYSTEM AIR COOLED REMOTE COOLER...
Страница 53: ...Section 7 ILLUSTRATIONS AND PARTS LIST 48 7 5 FLUID COOLING PIPING SYSTEM AIR COOLED REMOTE COOLER...
Страница 63: ...Section 7 ILLUSTRATIONS AND PARTS LIST 58 7 8 FLUID COOLING SYSTEM WATER COOLED 200 250HP 150 187K W...
Страница 65: ...Section 7 ILLUSTRATIONS AND PARTS LIST 60 7 8 FLUID COOLING SYSTEM WATER COOLED 200 250HP 150 187K W...
Страница 67: ...Section 7 ILLUSTRATIONS AND PARTS LIST 62 7 9 FLUID COOLING SYSTEM WATER COOLED 300 350HP 225 261K W...
Страница 69: ...Section 7 ILLUSTRATIONS AND PARTS LIST 64 7 9 FLUID COOLING SYSTEM WATER COOLED 300 350HP 225 261K W...
Страница 71: ...Section 7 ILLUSTRATIONS AND PARTS LIST 66 7 10 COMPRESSOR DISCHARGE SYSTEM...
Страница 73: ...Section 7 ILLUSTRATIONS AND PARTS LIST 68 7 10 COMPRESSOR DISCHARGE SYSTEM...
Страница 75: ...Section 7 ILLUSTRATIONS AND PARTS LIST 70 7 11 SULLICON CONTROL 250 350 HP 187 261 KW ONLY 200HP 150KW ONLY...
Страница 77: ...Section 7 ILLUSTRATIONS AND PARTS LIST 72 7 11 SULLICON CONTROL 250 350 HP 187 261 KW ONLY 200HP 150KW ONLY...
Страница 79: ...Section 7 ILLUSTRATIONS AND PARTS LIST 74 7 12 COMPRESSOR ACTUATOR...
Страница 81: ...Section 7 ILLUSTRATIONS AND PARTS LIST 76 7 13 ELECTRO PNEUMATIC CONTROL SYSTEM...
Страница 83: ...Section 7 ILLUSTRATIONS AND PARTS LIST 78 7 13 ELECTRO PNEUMATIC CONTROL SYSTEM...
Страница 85: ...Section 7 ILLUSTRATIONS AND PARTS LIST 80 7 14 ENCLOSURE...
Страница 87: ...Section 7 ILLUSTRATIONS AND PARTS LIST 82 7 14 ENCLOSURE...
Страница 89: ...Section 7 ILLUSTRATIONS AND PARTS LIST 84 7 15 UNIT TUBING...
Страница 91: ...Section 7 ILLUSTRATIONS AND PARTS LIST 86 7 16 DECAL GROUP 1 2 3 4 5 6 7 8 9 10...
Страница 95: ...Section 7 ILLUSTRATIONS AND PARTS LIST 90 7 16 DECAL GROUP 21 22 23 24 25...
Страница 97: ...Section 7 ILLUSTRATIONS AND PARTS LIST 92 7 16 DECAL GROUP 26 28 29 30 31...
Страница 102: ...Section 7 ILLUSTRATIONS AND PARTS LIST 97 7 20 WIRING DIAGRAM...
Страница 103: ...Section 7 ILLUSTRATIONS AND PARTS LIST 98 7 21 WIRING DIAGRAM WYE DELTA...