SYMPTOM
PROBABLE CAUSE
REMEDY
COMPRESSOR WILL NOT BUILD
UP FULL DISCHARGE PRESSURE
Air Demand is Too Great
Check service lines for leaks or open
valves.
Dirty Air Filter
Check the filter indicator and change
if required.
Pressure Regulator Out of
Adjust regulator according to control
Adjustment
adjustment instructions in the Maintenance
section.
Defective Pressure Regulator
Check diaphragm and replace if necessary
(kit available).
Defective or Dirty Inlet Valve
Check that valve fully opens when full air
demand is present. Repair or clean as
necessary.
LINE PRESSURE RISES ABOVE
CUT---OUT PRESSURE SETTING
ON PRESSURE SWITCH
Leak in Control System Causing
Loss of Pressure Signals
Check for leaks.
Defective Pressure Switch
Check that diaphragm and contacts are not
damaged. Replace if necessary.
Defective Solenoid Valve
Repair kit available.
Defective Blowdown Valve
Check that sump pressure is exhausted to
the atmosphere when the pressure switch
contacts open or repair or replace if
necessary (kit available).
High Pressure Shutdown Switch
is Defective or Adjustment is
Incorrect
Readjust or replace.
EXCESSIVE COMPRESSOR FLUID
CONSUMPTION
Clogged Return Line or Orifice
Clean strainer (screen and o---ring replace---
ment kit available).
Clean orifice.
Separator Element Damaged or
Not Functioning Properly
Change element.
Leak in the Lubrication System
Check all pipes, connections and
components.
Excess Fluid Foaming
Drain and change.
Fluid Level Too High
Drain to correct level.
PRESSURE RELIEF VALVE
OPEN REPEATEDLY
High Pressure Shutdown Switch is
Defective or Out of Adjustment
(135 PSIG [932kPa]).
Readjust below pressure relief valve setting
(200 PSIG [1379kPa]) or replace.
Defective Pressure Relief Valve
Replace pressure relief valve.
Check Separator Differential
(plugged)
Содержание 10B 25HP
Страница 2: ...NOTE For Additional Information on 24KT Units See Inside Back Cover...
Страница 4: ...NOTES...
Страница 13: ...Section 2 DESCRIPTION 7 Figure 2 3 Compressor Discharge Cooling and Lubrication System Water Cooled...
Страница 22: ...16 NOTES...
Страница 24: ...Section 4 INSTALLATION 18 Figure 4 1 Piping and Instruments...
Страница 26: ...20 NOTES...
Страница 42: ...36 NOTES...
Страница 44: ...NOTES...
Страница 45: ......