background image

11

10

ENGLISH 

ENGLISH 

Calle Verano, 51 - Polígono Industrial Las Monjas -28850 Torrejón de Ardoz - Madrid (ESPAÑA)

 

 

www.sulion.es

CIF  A28763647

+34 916774540

ATC: 

916749481 - [email protected]  /  

SAT :

 916749483 - [email protected]

Due to the fan’s movement, certain fastenings may become loose. Check all fastenings twice per year at a 

minimum in order to ensure that they are sufficiently tight. If necessary, they must be retightened.

If the power cord is damaged, it must be replaced by the manufacturer, its after-sales service or similar 

qualified personnel in order to avoid any malfunction.

Only suitable for indoors. 

Replaceable bulb / Replaceable LED

  

Replaceable driver

 

Replaceable receiver

Do not throw away electrical products together with household waste. We ask you to recycle the packaging 

at the collection points provided for this purpose. Contact local authorities or your provider for recycling 

advice. Thank you for recycling at the collection points provided for this manual.

Note: 

The important warnings and instructions indicated in this manual are not guaranteed to cover all possible conditions 

and situations that may occur. It must be understood that common sense, precaution, and care are factors that cannot be 

included in all products. These factors can and must only be provided by the user who maintains and enjoys this fan.

Nominal voltage and frequency

220-240V~AC 50/60Hz

Light wattage

36W

Luminous flux

2500lm

Light color temperature

3000/4000/6000K

Nº of light ON/OFF cycles

10000

Nº of hours of light lifespan

30000h

Protection category

Clase I

Protection index

IP20

Word temperature

-5 

 40ºC

Dimmable/Not dimmable

Not dimmable

Maximun ceiling slope on which it can be installed

  15º

Light angle

120º

Light Ra

>80

Weight

9,2kg

This product have a light source of energy efficiency class 

G

Preparing for installation

Note: 

The estimated installation time is 120 minutes. This product can only be installed by a certified electrician Carefully 

separate the fan’s parts, avoiding the use of cutters or blades that could scratch any part of it.

Device technical spectifications

Remote control

Syncing the receiver and the remote control for fan operation

If the receiver and transmitter of this fan are properly synchronized, the fan will work. During synchronization the receiver 

recognizes the signal from the transmitter, this is called the learning process.

Make sure the fan is disconnected. This is essential for the synchronization process.

Unless the synchronization process has been successful, the fan will work partially or will not work. By default, all fans have 

been preconfigured at the factory and should be functional once the installation is completed and the fan is turned on.

If the remote control does not work after installation or during use, synchronization can be performed as indicated below. Note 

in any case that there could be other reasons why your fan or remote control does not work:

  Make sure all connections are correctly made.

  Make sure that the remote control contains batteries.

  Make sure that all switches (main and isolation) are on.

Instructions for synchronizing the receiver and the remote control

The control of this fan does not require synchronization with the recelver, the control is already factory-linked with its receiver; 

Universal mode and Unit mode:

- Unit Mode:

This type of synchronization allows you to control two or more nearby fans independently, each with its remote control.

Synchronization:

The control of this fan does not require synchronization with the receiver, the control is already factory-linked with its receiver

- Universal Mode:

This type of synchronization allows you to control one or more nearby fans with the same remote control.

Synchronization:

1.-Connect the power (wall switch) of the fan or fans that you want to control, and then just within the following

15 seconds, press the key      of the remote control for 5 continuous seconds.

2.-A “beep” sound indicates that the connection has been executed and the equipment can function normally.

3.-Now, transmitter and receiver of the fan / s will have been synchronized. Turn off the fan / s current using the

switch or automatic and then turn it back on / s, this step is the one that closes the synchronization process.

It is not possible for a controller to forget a fan once it has been linked, if you want a fan to leave

to obey a command, another one must be linked to “overwrite it”.

Speed

1

2

3

4

5

6

Fan power (W)

5,1

7,5

10,4

14,4

19,3

26

Fan RPM

144

160

175

190

206

224

Fan airflow (m³/min)

63

88

95

135

145

150

Noise level (dB)

33

37

40

45

49

55

Service value SV ((m³ / min) / W)

12,3

11,7

9,1

9,3

7,5

5,7

Power consumption in standby mode (W)

<0,5

Service value measurement standard

EN 62879:2020

Remote control safety functions

Blocking protection

The remote receiver includes a function that automatically blocks motor operation, cutting current to the motor 30 seconds 

after detecting an obstruction in front of the fan that prevents normal operation. When this happens, you must remove the 

obstacles blocking the fan. Then, press the off button on the remote control to reset the receiver. Now you can continue to 

use the fan normally.

Note: 

Unless you remove the obstruction blocking the fan, it will not operate correctly.

Overload prtection

If the fan’s receiver detects that the motor is operating at greater than 80W (this indicates an overload), current to the motor 

will be cut automatically, which will immediately stop the fan. To reset the receiver, press the off button on the remote control.

Note:  

If the receiver goes into protection mode again, this may indicate a motor defect. Contact the supplier immediately. The 

duration of the warranty is indicated in the warranty document provided in this manual.

Содержание 075714

Страница 1: ...de encontrar s un acceso a v deos instrucciones y una gu a de preguntas frecuentes In the event of any questions incidents or missing parts before consulting with your retailer call our customer servi...

Страница 2: ...n pues se producir a mal funcionamiento del ventilador y o da os en su motor Para la conexi n el ctrica es preciso incorporar un interruptor seccionador de acuerdo con las reglamentaciones de instalac...

Страница 3: ...sonido de tipo beep indica que la conexi n ha sido ejecutada y el equipo puede funcionar normalmente 3 Ahora control remoto y receptores de los ventiladores habr n quedad sincronizados Quite la corri...

Страница 4: ...y la asistencia de un electri cista autorizado puede ser necesaria A El fusible est fundido o el interruptor de la instalaci n est abierto desconectando la alimentaci n el ctrica al aparato Verificar...

Страница 5: ...plir el uso al que est destinado el titular de la garant a tendr derecho a la sustituci n del objeto adquirido por otro de id nticas caracter sticas o la devoluci n del precio pagado T rminos y condic...

Страница 6: ...during use synchronization can be performed as indicated below Note in any case that there could be other reasons why your fan or remote control does not work Make sure all connections are correctly m...

Страница 7: ...tely tightened Check that wiring connections have been done correctly They must be carried out by a certified electrician C The remote control is unresponsive Replace the remote control battery if nec...

Страница 8: ...efficacit nerg tique Ce ventilateur fonctionne en courant continu DC ce qui lui permet d tre d une grande efficacit nerg tique tout en produisant un grand volume de circulation d air de mani re silenc...

Страница 9: ...chronisation le r cepteur reconna t le signal de l metteur c est ce qu on appelle le processus d apprentissage Assurez vous que le ventilateur est d branch Ceci est essentiel pour le processus de syn...

Страница 10: ...ation est ou vert ce qui d connecte l alimentation lectrique l appareil V rifiez l tat des fusibles et des disjoncteurs du circuit d alimenta tion de l installation de l appareil B Le raccordement de...

Страница 11: ...se s engage r parer gratuitement et totalement les d fauts caus s et les dommages et pr judices occasionnn s directement par ceux ci De m me si la r paration n est pas satisfaisante et l objetnerempli...

Страница 12: ...enos que o processo de sincroniza o tenha sido bem sucedido o ventilador funcionar parcialmente ou n o funcionar Por padr o todos os f s foram pr configurados na f brica e devem estar funcionando uma...

Страница 13: ...t fundido ou o interruptor da instala o est aberto desligando a liga o el trica do aparelho Verificar o estado dos fus veis e dos interruptores do circuito de alimenta o desde a instala o at ao aparel...

Страница 14: ...s caracter sticas ou a devolu o do pre p que pagou Termos e condi es de garant a www sulion es Gratulation zu Ihrem Kauf Herzlichen Gl ckwunsch zum Kauf der neuesten energieeffizienten Deckenventilato...

Страница 15: ...ers und der Fernbedienung f r den L fterbetrieb SWenn der Empf nger und der Sender dieses L fters ordnungsgem synchronisiert sind funktioniert der L fter W hrend der Syn chronisation erkennt der Empf...

Страница 16: ...ie gegebenenfalls die Batterie der Fernbedienung Andernfalls m ssen Sender und Empf nger neu synchronisiert werden D Keine Stromversorgung Vergewissern Sie sich dass das System mit Strom versorgt wird...

Страница 17: ...ein neues Ger t von identischen Eigenschaften oder die Erstattung des Kaufpreises verlangen Allgemeine Bedingungen f r die Gew hrleistung www sulion es Complimenti per l acquisto Congratulazioni per...

Страница 18: ...il controllo remoto Se il ricevitore e il trasmettitore di questa ventola sono sincronizzati correttamente la ventola funzioner Durante la sincronizzazione il ricevitore riconosce il segnale dal trasm...

Страница 19: ...B I cavi del sistema non sono collegati adeguatamente Controllare che i collegamenti siano stati effettuati correttamente Questi controlli devono essere effettuati da un elettricista qualificato C Il...

Страница 20: ...a pu causare rumore eccessivo e oscillazioni che non saranno coperte della garanzia Eseguendo una manutenzione regolare per stringere questi elementi e pulire attentamente pu prevenire questi problemi...

Страница 21: ...s SULION declara sobre a sua pr pria responsabilidade que os produtos indicados a seguir foram fabricados em conformidade com os seguintes padr es europeus SULIONerkl rtineigenerVerantwortung dassdien...

Страница 22: ......

Отзывы: