8 Safety inspection

Important: To ensure safety, read section one “ 1

  For your safety!“ first.

To ensure safe operation, please perform the following inspections before use.
If any fault or malfunction is discovered, please take measures immediately.

Inspection

Measure

Is the electric cord damaged or deformed?

Change the cord after having consulted with an 

authorized electrician.

Is the plug deformed or broken?

Change the plug after having consulted with an 

authorized electrician.

Is the cord and the power source connected cor-

rectly?

If not, connect them correctly.  

Are the ducts deformed or torn?

Change them for new ones.

Is the filter clogged with dust or dirt?

Clean the filter.

Is the filter installed correctly?

If not, install it correctly.

Is the filter torn or damaged?

Change it for a new one?

Is the fin of the heat exchanger broken?

Hand the unit in for inspection and repair at your local 

retailer.

Is the heat exchanger fin covered with dust or 

greasy dirt?

Is the filter or cool air duct blocked?

Remove the obstructing object.

Is the drain tank installed correctly?

If not, Install it correctly.

Is the drain tank damaged?

Change it for a new drain tank.

Are the caster wheels worn out?

Change the caster wheels.

Are the caster stoppers working normally?

If not, change the caster wheels.

Are all the switches and buttons working properly?

If not, consult page 13 of this manual and follow 

the instructions. If the problem remains even after 

that, please consult with your local dealer regarding 

inspection and repair.

Is the unit emitting strange sounds or smells?

Please consult with your local dealer regarding 

inspection and repair.

Содержание SS-22DD-8A

Страница 1: ...0 After service 14 Index Thank you for purchasing this product from the world brand SUIDEN Please use this product correctly after having thoroughly read this manu al After having finished reading ple...

Страница 2: ...in water leakage and a short circuit Testing and operating the unit Warning Please do not use the unit close to kerosene gasoline thinner ether paints or other flammable or explosive objects This can...

Страница 3: ...e unit if the cord or plug is damaged or if the plug is loose in the socket Electric shock or fire caused by a short circuit can occur If you use an extension cord make sure to use one that meets the...

Страница 4: ...use it instead Caster wheel with brake Drain tank Filter cover Electric cord earthed 2 0m complete with plug Caster wheel Earth terminal Service box Handle Control panel Filter Interior part Filter e...

Страница 5: ...uct elbow is not attached evenly reattach it correctly 2 Attaching the cold air duct I Insert the cold air duct into the duct elbow fitting the attach ment peg on the duct to the attachment notch in t...

Страница 6: ...parts and cause malfunction Do not block the exhaust air vent in any way This will obstruct the function of the unit and cause malfunction Note If you will make an opening for the duct extension in th...

Страница 7: ...extension to the cool air duct narrow the end until the gap is completely sealed then tighten the duct strap III Attach the accessory cool air duct extension cap onto the duct extension with glue Atta...

Страница 8: ...stment switch and the swivel switch to make sure that everything works properly I The properties of all the switches are explained further in the next section How to use II If the unit does not work p...

Страница 9: ...ed approximately 300 degrees Vertical adjustment The cool air duct is flexible and can be bent in any desired way within its possible range Note I Bend the cool air duct gently firmly holding the duct...

Страница 10: ...r cold part of the heat exchanger on the front of the unit vaporises when it passes through the warm lower part on the way down to the drain tank In certain environments almost all water will vapor iz...

Страница 11: ...relay protects the compressor from overcurrents and overheating engine II The compressor overload relay is automatic If the overload relay starts to work frequently and the unit stops working please t...

Страница 12: ...oil mist filter prevents deterioration of cooling effect caused by the heat exchanger becoming greasy and prevents the condensed water from scattering 2 External maintenance I Wipe the ducts and other...

Страница 13: ...not install it correctly Is the filter torn or damaged Change it for a new one Is the fin of the heat exchanger broken Hand the unit in for inspection and repair at your local retailer Is the heat ex...

Страница 14: ...fore turning on the COOL again This does not apply to AIR which can be turned on immediately Is the voltage too low Consult with your electric company The unit turns itself on and off frequently The o...

Страница 15: ...you commence Inaccurate or inappropriate use can cause the quality of the objects to deteriorate Sometimes it will be necessary to perform installation work and electric work to the unit In these cas...

Отзывы: