32
If the server system fails (ERR information displays) under any menu, the LCD module will
flicker alternatively under the red and white background light for alarm. In addition, the
system will automatically add ERROR INFORMATION menu to the L1 menu column. Under
the initial status, to continuously press the key
6 times, the ERROR INFORMATION menu
will display. To press
key, ERROR INFORMATION L2 sub-menu will display. Otherwise, to
press key
under ERROR INFORMATION L1 menu, the system will return to the initial
interface.
To enter ERR INFORMATION L2 sub-menu, the LCD module will display SYS ERR. To press
key
in turn, the LCD will display ERR information in cycle. To press key
on any phase
of L2 sub-menu, the system will return to ERR INFORMATION L1 menu.
The specific failure information will display, shown as the table 3-2.
Table 3-2 Failure information report
Alarm information
Information description
SYS ERR
System error
VOLTAGE ERR
Voltage error
FAN ERR
Fan error
CPU ERR
CPU error
RAM ERR
Memory error
3.2 Eliminate CMOS jumper setting
The J3 jumper can be used to eliminate the CMOS setting on the mainboard. You can clear
CMOS according to the following table:
Table 3-3 CMOS jumper clearing description
The jumper will be under this position by default. At this time, the
system will normally work.
When CMOS will be cleared, the jumper will be cleared as this
step. The jumper will set the jumper by default after 3-5s.
【
Notice
】
Before the J3 jumper is short circuit and CMOS is cleared, make sure to fully
shut down the system and plug off the AC power cable and onboard battery.