Page 41
2
For each broiler element, use an ohmmeter to check
between the broiler element terminals.
The resistance should be ~ 65 Ω.
3
If the resistance is more than 10% different from the
specification, replace the broiler element.
TEST THE NOISE FILTER
1
Disconnect the wire connectors from the noise filter
terminals.
2
Use an ohmmeter to check between the terminals:
Terminals
Reading
N and L
Open
N and WHITE
Continuity
L and RED
Continuity
3
If the readings are different from the values in the table,
replace the noise filter unit.
Speed Oven
Troubleshooting
TEST THE BROILER ELEMENT (continued)
service.subzero.com
828422 REV. A 03/2019
40
Содержание WOLF SPO
Страница 44: ...Speed Oven Wiring Diagrams Speed Oven Wiring Diagrams service subzero com 828422 REV A 03 2019 43...
Страница 45: ...Speed Oven Wiring Diagrams Speed Oven Wiring Diagrams service subzero com 828422 REV A 03 2019 44...
Страница 46: ...Speed Oven Wiring Diagrams Speed Oven Wiring Diagrams service subzero com 828422 REV A 03 2019 45...
Страница 47: ...Speed Oven Wiring Diagrams Speed Oven Wiring Diagrams service subzero com 828422 REV A 03 2019 46...
Страница 48: ...Speed Oven Wiring Diagrams Speed Oven Wiring Diagrams service subzero com 828422 REV A 03 2019 47...
Страница 49: ...Speed Oven Wiring Diagrams service subzero com 828422 REV A 03 2019 48...