electrical cOnnectiOn
(re-ignitOr MODelS)
A.
Applicable to models: SW6 & SW10PR or PER.
B.
Make 12 volt D.C. connections to re-ignitor as
illustrated in Figure 12.
It is recommended to use insulated terminals for all
electrical connections.
Figure 12
ligHting inStructiOnS FOr reignitOr MODelS
OPERATING AND LIGHTING INSTRUCTIONS
APPLICABLE TO MODELS SW6PR • SW10PR • SW6PER • SW10PER
Warning!
If you do not follow these instructions exactly, a fire or explosion may result
causing property damage, personal injury or loss of life.
1. STOP!
Read the safety information provided. (Refer to PREVIOUS PAGE)
2.
Place reignitor control in the “OFF” Position.
3.
Depress and turn knob (A) clockwise
]
to “OFF” position.
4.
Turn off all electric power to the appliance (gas/electric models only).
5.
Wait five(5) minutes for gas to clear the area. If you smell gas then
STOP!
Follow instructions in items B on the previous
page under
SAFETY INFORMATION
. If you do not smell gas, go to the next step.
6.
Turn gas supply on.
7.
Turn on electrical power to the appliance.
8.
Depress and turn knob (A) counter clockwise
\
to “Pilot” position, press down and switch the electric reignitor module
to “ON” position. Spark will start between electrode tip and pilot hood.
9.
When pilot lights, the spark will stop. Continue depressing knob (A) for approximately one minute or until pilot light
remains lit. On the initial start-up, it may take several minutes in order to purge the air from the gas lines and the pilot
remain on.
10.
Depress and turn knob (A) counter clockwise
\
to “ON” position. The control knob has a straight line designation
beyond the “ON” position. Turn to this position when moving the valve from the “Pilot” position to the “ON” position.
11.
Set temperature dial (B) to desired setting.
CAUTION: Temperature setting on control was factory set
at low (120°F/49°C) to reduce risk of scald injury. Setting
the temperature dial past the low position will increase
the risk of scald injury. Children, disabled, elderly and
diabetics are at highest risk of being scalded.
NOTE:
When the reignitor switch is in the “ON” posiion, the
reignitor will operate automatically when the pilot flame is
extinguished.
NOTE:
When the vehicle is to be stored or the LP gas supply
is to be turned off, be sure to turn the reignitor control switch
to the “OFF” position. This will prevent the battery from being
discharged (the reignitor will continue sparking).
NOTE:
The reignitor has an alarm which will sound when
the pilot is extinguished or if the LP supply is turned off. The
alarm will serve as a reminder to turn off the reignitor.
TO TURN OFF WATER HEATER
1. Turn temperature dial (B) clockwise
]
to the lowest setting.
2. Turn off the reignitor.
3. Turn off electrical power to the appliance.
4. Depress and turn knob (A) clockwise
]
to the “OFF” position.
5. If vehicle is to be stored or heater is going to be turned off while subject to freezing temperature, drain water heater.
(See “Draining and Storage Instruction”)
INSTRUCTIONS
FOR YOUR SAFETY
WARNING HOT
3
5
4
2
I
FOR LIGHTING
4
5
2
3
LIGHTING
I
+
ON
-
SPARK WIRE
LIGHT PILOT
HERE
C
B
A
REIGNITOR CONTROL SWITCH
12 VOLT WIRE CONNECTION
GROUND WIRE
ELECTRODE WIRE CONNECTION