13
Figure 6
Figure 6A
VEnT aSSEMblY inSTallaTiOn (SFV MODElS)
STANDARD VENT ASSEMBLY FURNISHED WITH FURNACE. SPECIAL EXTENSION TUBES, IF
NEEDED, MUST BE ORDERED SEPARATELY. EXTENSION KITS COME WITH COMPLETE
INSTALLATION INSTRUCTIONS.
USE VENT SUPPLIED WITH FURNACE
EXTENSION TUBES KIT NO.
7 1/2" TO 9"
4 1/2" TO 7 1/2"
3" TO 4 1/2"
1 1/2" TO 3"
0" TO 1 1/2"
X" DIMENSION
520769
520551
520768
VENT CAP
EXHAUST
& INT
AKE
LC
TRAILER SKIN
SFV-20, 25, 30, 35, 42 VENT INSTALLATION FOR VERTICAL MOUNT
SURFACE
MOUNTING
"X"
2
3
4
"
DIA.
1.000
TYP
.
NEVER INSTALL THE EXHAUST TUBE
WITH LESS THAN 1 1/4" OVERLAP, OR
THE INTAKE TUBE WITH LESS THAN
1/2" OVERLAP.
HOT
SUBURBAN
BRACKET REAR VERTICAL
MOUNTING-USE IF POSSIBLE
BRACKET, CABINET MOUNTING
(ONE PER SIDE)
051249
DO NOT
BLOCK OPENINGS
GASKET, BOTTOM DUCT
THICKNESS
8.000"
3.375"
2.062"
18.750"
VENT CAP & EXHAUST TUBE
WITH GASKET
DETAIL "A"
(SECURE WITH 6 SCREWS)
REMOVABLE PANEL OF COACH WALL
MUST SEAL WATER TIGHT
WITH GASKET
CL
L
C
FURNACE
CUTOUT
ANCHOR FURNACE TO FLOOR USING THE
(4) #10 X 3/4 SCREWS PROVIDED
(2) 2.250 DIA. HOLES
2.000" MAX. WALL
TUBE, AIR INTAKE
2.060"
SECURE CABINET MOUNTING BRKTS TO CABINET
WITH (2) #8 X 1/2 SCREWS
INSIDE WALL
CAULK BEHIND VENT CAP AS SHOWN TO SEAL BETWEEN
EXHAUST AND INTAKE AND TO PREVENT MOISTURE INSIDE
FURNACE COMPARTMENT. APPLY CAULKING GENEROUSLY
AROUND PERIMETER OF VENT CAP AND ACROSS CENTER
AS SHOWN. CENTER PUTTY STRIP IS ESSENTIAL.
SEE DETAIL "A"
OUTSIDE SKIN (PANEL)
FURNACE CABINET
FRONT
RAIN SHIELD INSTALLATION:
APPLY CAULKING BETWEEN RV SKIN AND BACK OF RAIN SHIELD.
POSITION RAIN SHIELD AS ILLUSTRATED. APPLY A SECOND LAYER
OF CAULKING OVER RAIN SHIELD AND BEHIND VENT CAP AS
ILLUSTRATED. FOLLOW INSTRUCTIONS FOR CAULKING VENT.
TUBE, INTAKE AIR
REMOVABLE PANEL
VENT CAP & EXHAUST TUBE
ELECTRICAL CONNECTION
GAS CONNECTION (REAR) (SFV-35)
FLOOR
OUTSIDE SKIN (PANEL)
3.750
2.060
RIGHT SIDE
OF CUTOUT
GAS CONNECTION (FRONT) (SFV-35F)
CUT OUT AS VIEWED
FROM INSIDE R.V.