12
Figure 5
Figure 5A
8.281"
2.000" MAX.
18.218"
BACK OF CABINET MUST BUTT
AGAINST THIS EDGE OF FRAME
DOOR FRAME
SECURE FRAME TO OUTER PANEL
WITH SCREWS (16 PLACES)
4 SCREWS
DOOR MOUNTING
FURNACE ACCESS DOOR
AIR INTAKE TUBE WITH GASKET
VENT CAP & EXHAUST TUBE
CAULK ALONG THE EDGE OF THE
CUTOUT (ALL THE WAY AROUND)
6 SCREWS SUPPLIED
ELECTRICAL CONNECTION
GAS CONNECTION
(REAR)
FURNACE
FLOOR
ANCHOR FURNACE
TO FLOOR USING
(2) #10 X 3/4
SCREWS PROVIDED
TIE-DOWN SCREW
OUTSIDE SKIN
(FURNACE TO CABINET)
SPACERS ON LEFT SIDE
OF FURNACE ARE FLUSH
WITH LEFT SIDE OF
CUTOUT
CABINET MOUNTING
BRACKET
CAULK BEHIND VENT CAP AS SHOWN TO SEAL BETWEEN EXHAUST
AND INTAKE AND TO PREVENT MOISTURE INSIDE FURNACE
COMPARTMENT. APPLY CAULKING GENEROUSLY AROUND PERIMETER
OF VENT CAP AND ACROSS CENTER AS SHOWN. CENTER PUTTY STRIP
IS ESSENTIAL.
*
*
BRACKET
GAS CONNECTION
(FRONT)
.625 MIN. (THICKNESS)
8.313
MIN.
**NOTCH DETAIL**
FLOOR AND OUTER SKIN
MUST BE NOTCHED AS
SHOWN BELOW.
.220 MIN. (HEIGHT)
(WIDTH)
DETAIL A
(ONE PER SIDE)
CABINET MOUNTING
L
C
.375
2.062
**.220
MIN.
2.060
8.281
CUTOUT AS VIEWED FROM OUTSIDE
R.V.
*
*
CUTOUT FOR FURNACE ACCESS DOOR FRAME
FLOOR
18.218
FURNACE
3.375
CL
*
BRACKET
ANCHOR BRACKET
TO FLOOR USING
(2) #10 X 3/4
SCREWS PROVIDED
CABINET SUPPORT BRACKET
WELDED TO CABINET
** SEE NOTCH DETAIL A
VEnT aSSEMblY inSTallaTiOn (SFV MODElS)
SFV-20F, 25F, 30F, 35F, 42F VENT INSTALLATION FOR VERTICAL MOUNT
STANDARD VENT ASSEMBLY FURNISHED WITH FURNACE. SPECIAL EXTENSION TUBES, IF NEEDED, MUST BE
ORDERED SEPARATELY. EXTENSION KITS COME WITH COMPLETE INSTALLATION INSTRUCTIONS.
USE VENT SUPPLIED WITH FURNACE
EXTENSION TUBES KIT NO.
7 1/2" TO 9"
4 1/2" TO 7 1/2"
3" TO 4 1/2"
1 1/2" TO 3"
0" TO 1 1/2"
X" DIMENSION
520769
520551
520768
520767
VENT CAP
EXHAUST
& INT
AKE
LC
TRAILER SKIN
SURFACE
MOUNTING
"X"
2
3
4
"
DIA.
1.000
TYP
.
NEVER INSTALL THE EXHAUST TUBE WITH LESS
THAN 1 1/4" OVERLAP, OR THE INTAKE TUBE
WITH LESS THAN 1/2" OVERLAP.
HOT
SUBURBAN
DO NOT
BLOCK OPENINGS
BRACKET REAR VERTICAL
MOUNTING-USE IF POSSIBLE
BRACKET, CABINET MOUNTING
(ONE PER SIDE)
GASKET, BOTTOM DUCT