background image

ii

SSCI - Suburban Surgical Company, Inc.

Table of Contents

Cleaning Instructions ................................................................................................................. 16

Introduction .................................................................................................................. 16
Stainless Steel Cleaning Procedures .............................................................................. 16
Clear Polycarbonate Cleaning Procedures ..................................................................... 16
Ice Tray Cleaning Procedures ....................................................................................... 16
Nebulizer Cleaning Procedures ..................................................................................... 16

Chapter 4 - Repairs and Replacements ....................................................17

Replacement Parts .................................................................................................................... 17
General Information .................................................................................................................. 18
Parts Ordering Procedure ......................................................................................................... 18
Procedures ............................................................................................................................... 19

Nebulizer Assembly, Complete ...................................................................................... 19

Tool Required ............................................................................................. 19
Procedure .................................................................................................. 19

Nebulizer Assembly, Partial ........................................................................................... 20
Nebulizer Oxygen Supply Hose .................................................................................... 20
Nebulizer Hose Barb Fitting .......................................................................................... 21

Tools Required ........................................................................................... 21
Procedure .................................................................................................. 21

Nebulizer Extension ...................................................................................................... 22
Nebulizer Cotter Pin ..................................................................................................... 22
Gauge Assembly ........................................................................................................... 22

Overview ................................................................................................... 22
Tools Required ........................................................................................... 22
Removal - Old-style Gauge ......................................................................... 22
Removal - New-style Gauge ....................................................................... 23
Installation of New-style Gauge ................................................................... 23

Ice Tray ........................................................................................................................ 25
Ice Tray Valve .............................................................................................................. 25

Tools Required ........................................................................................... 25
Procedure .................................................................................................. 25

Seal Strip Retainer and Seal Strip .................................................................................. 26

Parts Identification ...................................................................................... 26
Tools Required ........................................................................................... 26
Procedure .................................................................................................. 26

Chapter 5 - Troubleshooting .....................................................................29

General .................................................................................................................................... 29
Returning the Oxygen Therapy Door for Repairs ....................................................................... 30

RMA Numbers ............................................................................................................. 30
Packing and Shipment ................................................................................................... 30

There is no oxygen flow into the cage. ....................................................................................... 31
There is excessive oxygen leakage from the cage. ...................................................................... 32
The door does not close or latch correctly. ................................................................................ 33
One or both of the gauges does not read correctly. .................................................................... 34

Содержание OXYGEN THERAPY DOOR 12155-00-DRDRAA

Страница 1: ...ometer hygrometer Outside compartment for nebulizer and ice New Model Numbers 12155 00 DRDRAA 12155 00 DREPAA 12155 00 EPDRAA 12155 00 EPEPAA 12155 00 EPFNAA 12155 00 EPHJAA 12155 00 FNFNAA 12155 00 F...

Страница 2: ...including photocopying recording or by any information storage and retrieval system without written permission Inquiries should be addressed to Suburban Surgical Co Inc Wheeling Illinois 60090 USA Wa...

Страница 3: ...nty 4 Safety 4 CleaningRequirements 4 SSCIContactInformation 5 Warranty 5 Chapter 2 Installation and Setup 7 UnpackingandInspection 7 PartsIncluded 7 InstallationandSetup 7 ToolsRequired 7 Procedure 8...

Страница 4: ...NebulizerHoseBarbFitting 21 ToolsRequired 21 Procedure 21 NebulizerExtension 22 NebulizerCotterPin 22 GaugeAssembly 22 Overview 22 ToolsRequired 22 Removal Old styleGauge 22 Removal New style Gauge 23...

Страница 5: ...onatedoorallowsyoutoviewtheanimalatalltimes A detachable compartment on the outside holds the oxygen nebulizer and ice to cool the oxygen if needed The door mounts onto the front of the cage in place...

Страница 6: ...n any area in which oxygen is being used TheSSCIOxygenTherapyDoorisavailableineightdifferent models based on Regal cage sizes Note Dimensions shown in Table 1 are cage sizes Notes Models Table 1 Model...

Страница 7: ...appearance Ordinarydepositsofwasteandfluidscanusuallyberemovedwith soap and water More stubborn deposits or tightly adhering debris mayrequireharderscrubbingandpossiblytheuseofcommercial cleaningprod...

Страница 8: ...rides suchaschlorinebleach bromides iodides and thiocyanates on stainless steel surfaces as thesechemicalswillcausepitting corrosionandmetaldiscoloration Allowingsaltysolutionstoevaporateanddryonstain...

Страница 9: ...r products are of the highest standards in material and workmanship Our stainless steel components are guaranteed to last alifetimeassumingtheyareusedasintended properlymaintained andcaredfor Mechanic...

Страница 10: ...6 SSCI Suburban Surgical Company Inc Chapter 1 General Information Comments...

Страница 11: ...rapyDoorwhileyouunpackit If damage is noted or if parts appear to be missing call SSCI Customer Service at 800 323 7366 Thefollowingpartsareincludedintheshipment Figure1 OxygenTherapyDoor Icetraywithv...

Страница 12: ...ART from the battery compartment Thegaugewillbeginoperating 4 Hangtheoxygentherapydoorontheexistingcagehinges andinstalltheoriginalhingepins Figure4 5 Hang the ice tray on the button hooks provided on...

Страница 13: ...cotter pin ends apart to keep the pin from falling out 10 Attach the free end of the nebulizer plastic tubing to a 50psiwalloxygenoutletoranoxygencylinder Note Your oxygen supplier is the best source...

Страница 14: ...10 SSCI Suburban Surgical Company Inc Chapter 2 Installation and Setup Comments...

Страница 15: ...thedoor anditmaynotlockautomatically when closed To adjust the door loosen the bracket screws Figure 9 move the brackets slightly up or down as needed then retighten the screws Try the door again and...

Страница 16: ...geislocatedontheupperleftofthe oxygen therapy door Figure 11 This battery powered gauge includesathermometerandahygrometertoallowyoutomonitor cagetemperatureandhumidityforoptimaltreatmentconditions In...

Страница 17: ...ing the Gauge Battery Figure 12 Gauge Buttons Max Min Button Clear Button Front View of Gauge A slide switch on the side of the gauge Figure 13 allows you to selectbetween Centigradeand Fahrenheittemp...

Страница 18: ...ncentrations ofoxygen Note Thenebulizerisdesignedforsinglepatientuse only Follow the steps below to use the nebulizer 1 Unscrew the bottle from the cap 2 Fillthebottletothe Maximum linewithsterile wat...

Страница 19: ...r Part Number 5007P Asimpleregulatorcollaronthenebulizerallowsyoutocontrolthe oxygen percentage concentration in the cage from 28 to 98 Simplyrotatetheregulatorcollaronthenebulizertothe approximate de...

Страница 20: ...oroughlywithcleansoftcloths Avoidprolongeduseofchlorides suchaschlorinebleach bromides iodidesandthiocyanates Neverallowsaltysolutionsto dry on the stainless steel Note NEVER power wash the oxygen the...

Страница 21: ...er to Page 23 e m a N t r a P r e b m u N t r a P I C S S o t r e f e R n o i t a m r o f n I r o F e t e l p m o C y l b m e s s A r e z i l u b e N 6 2 1 2 1 2 9 1 e g a P l a i t r a P y l b m e s...

Страница 22: ...equipment accessories and or replacement parts from your local dealer or directly through SSCI Customer Service You can order by mail telephone or fax Refer to Contact Information on Page 5 for addres...

Страница 23: ...e a needle nose pliers to squeeze the two ends of the cotter pin together then remove thepinfromtheextension Figure19 2 Open the oxygen therapy door 3 Placethenebulizerintheicetraywiththeextension thr...

Страница 24: ...lsoorderanewextension P N754061 The cotter pin supply hose and barb fitting can be transferred from your old nebulizer however the extension is bonded in place and difficulttoremove This 1 4 in ID 3 8...

Страница 25: ...eoxygensupplyhoseoffthefitting 2 Hold the white 4 arm knob on top of the regulator and unscrew the barb fitting with a 5 8 in open end wrench Nebulizer Hose Barb Fitting P N 854546 3 Toinstallthenewfi...

Страница 26: ...In an emergency use a bent paper clip as a temporary replacement Overview Theoriginalgaugewasasquare analog typeinstrument Thisgauge is no longer available and has been replaced by a smaller more mode...

Страница 27: ...w style Gauge P N 854771 Gauge Bracket P N 600162 2 Note Order a new gauge bracket only if replacing an old stylegauge Ifreplacinganew stylegauge useyour existingbracket 2 Loosely mount the gauge brac...

Страница 28: ...ge 8 Smooth out the outside and inside edges of the holes to eliminateanyroughedges 9 Remove the tape marked REMOVE TO START from the battery compartment When the tape is removed the gaugewillbeginope...

Страница 29: ...Remove the ice tray from the oxygen therapy door 2 Iftubingisattachedtothevalvebarbfitting pullorcut itoff 3 Holding thevalvebodywithapliers unscrewthevalve fromthetray 4 Screw the new valve into the...

Страница 30: ...ipsscrewdriver Procedure Note You do not have to remove the door from the cage to replace a seal strip retainer or a seal strip 1 Open the oxygen therapy door 2 With a 3 8 in wrench and a Phillips scr...

Страница 31: ...s e d i S L R 2 A A R D P E 0 0 5 5 1 2 1 N P w e N 1 4 6 5 2 0 1 N P d l O H n i 4 2 x W n i 0 3 H m c 6 9 0 6 x W m c 0 2 6 7 7 6 3 5 0 6 m o t t o B p o T 2 5 6 3 5 0 6 s e d i S L R 2 A A P E P E...

Страница 32: ...p o T 2 0 1 9 0 5 7 s e d i S L R 2 A A P E P E 0 0 5 5 1 2 1 N P w e N 1 7 6 5 2 0 1 N P d l O H n i 0 3 x W n i 0 3 H m c 0 2 6 7 x W m c 0 2 6 7 2 3 8 0 5 7 s e d i S 4 l l A 4 A A N F P E 0 0 5 5...

Страница 33: ...flow into the cage Page 31 There is excessive oxygen leakage from the cage Page 32 The door does not close or latch correctly Page 33 One or both of the gauges does not read correctly Page 34 Page num...

Страница 34: ...rom him before shipping the unit back Note SSCI will not accept merchandisereturnedwithoutanRMAnumber If you were able to keep the door shipping carton repack the door into the carton staple or tape t...

Страница 35: ...at the oxygen source call your oxygen supplierforrepairs b If the leak is in the oxygen supply hose call SSCI and order a replacement hose P N 750492 Refer to Page 20 for replacement procedures c If...

Страница 36: ...rly closed and latched If the door does not close or latch properly the latch brackets are probably out of adjustment Refer to Latch Adjustment on Page 11 Second Make sure the oxygen supply pressure i...

Страница 37: ...702703 Rev E August 2006 33 Owner s Manual Oxygen Therapy Door The door does not close or latch correctly The latch brackets are probably out of adjustment Refer to Latch Adjustment on Page 11 Remedia...

Страница 38: ...oting One or both of the gauges does not read correctly Remedial Action One or both of the gauges is defective The gauges are not repairable and must be replaced Call SSCI and order a new gauge assemb...

Страница 39: ...Inside back cover Thispageleftblankintentionally...

Страница 40: ...mpany Inc 275 Twelfth Street Wheeling IL 60090 Phone 847 537 9320 Fax 847 537 9061 Toll Free 800 323 7366 Web www suburbansurgical com SSCI For more information on SSCI s fine line of products and acc...

Отзывы: