www.ssilocators.com
06
SERIES
To select the desired frequency set for
software
versIons
3.43
and
Greater
:
• Press and hold depressed the
P
ower
o
n
Button.
• Pressing the
f
requency
B
utton
will toggle through available configurations. Repeat pressing until '
U5
' is displayed in
the Frequency Indicator section of the LCD.
• Release the
P
ower
o
n
Button. '
PRO
' will be displayed on the LCD.
• Press the
f
requency
B
utton
to toggle through the available frequencies.
• To select and store the desired frequency press and hold the
f
requency
B
utton
for 2 seconds. The count of the
selected frequency will be displayed on the LCD.
• Continue to toggle through and select the desired frequencies,
• Press the
P
ower
o
n
Button to shut the unit off. This will save the selected frequencies for availability during normal
operation.
The PL-VF operating modes, frequencies and other functions are user programmable and can be changed at anytime
through a quick selection process in the programming menu.
To select the programming options for
software
versIons
5.0
and
Greater
:
• With the unit on, press and hold the
P
ower
o
n
button for 4 seconds. Once released "
PRO
"' will be displayed at the
top of the LCD.
• To scroll through the main menu headings, press the
f
requency
/f
unctIon
K
ey
.
• To enter a selection's sub-menu press the
u
P
a
rrow
(G
aIn
u
P
)
Key
.
• To browse a selection’s menu, press the
f
requency
/f
unctIon
K
ey
.
• If the sub-menu, once the desired option is selected, then exiting the sub-menu after toggling to the desired setting, will
save the selection.
• To exit a selection's sub-menu use the
d
own
a
rrow
(G
aIn
d
own
)
button
.
• Exit the programming menu from the main menu by pressing the
P
ower
o
n
button. This return to the normal operation
mode.
C
hanging
p
reset
f
unCtions
, m
odes
& f
requenCies
r
eCeiver
t
ransmitter