www.ssilocators.com

04

SERIES

Congratulations on the purchase of your new SubSurface Instruments, Inc. PL-VF Series Cable, Pipe & Fault 

Locator. The PL-VF PLS Locator is specially designed to detect conductors such as buried pipes & cables. This 

device may detect buried power cables, CATV cables, gas and water pipes, sewer lines, telecommunication 

lines, fiber optic cables with sheath, sondes, inspection camera transmitters. You have chosen a quality 

product that is designed for years of field use without the need for annual or periodic calibration and service.

The basic principle of the locator's operation is as follows:

The 

T

ransmiTTer

 emits a signal to a conductive cable or pipe. The 

r

eceiver

 detects the electromagnetic field 

that is generated by the transmitted signal. You can locate the relative position of the buried utility by 

following the tracing signal.

For safely & to help ensure the best locating results, please read & understand the manual in its entirety 

before using the product. 

SubSurface Instruments, Inc. shall not be liable to Distributor, Re Seller, or any other person for any 

incidental, indirect, special, exemplary or consequential damages, or injury of any type whatsoever, and 

caused directly or indirectly by Products sold or supplied by SubSurface Instruments, Inc..

Failure to follow these warning could result in serious injury or death.

Only persons qualified and trained to operate cable & pipe locators may operate this equipment. 

Follow appropriate safety procedure, your companies policies and applicable safety codes and/or laws.

Do not connect to utilities, cables or pipes without authorization and training.

Use tool only for intended purpose as described in this manual

Do not expose tool to rain or moisture.

Do not expose to hazardous chemicals, hazardous gas or explosive environment.

SHOCK HAZARD - Lethal voltages may be present at the transmitter's output. Turn off transmitter before 

touching test lead or any un-insulated conductor. Make connection to ground and target conductor before 

turning on transmitter. 

SHOCK HAZARD - Do not connect to live voltage or active utility lines. De-energize any circuits in or around 

the work area.

This tool is designed to detect electromagnetic field emitted from cables and buried metallic utilities. There are 

buried cables, pipes, and utilities this instrument CANNOT detect.

LOCATING is not an exact science. The only certain way to be sure of the existence, location, or depth of 

buried utilities is to carefully expose (dig up) the utility.

WARNING!

WARNING!

WARNING!

WARNING!

WARNING!

WARNING!

WARNING!

WARNING!
WARNING!

WARNING!
WARNING!

i

ntroduCtion

d

isClaimer

 o

f

 l

iability

i

mportant

 n

otiCes

Содержание PL-VF Series

Страница 1: ...SERIES SERIES Instructions Functions and Warranty Information Pipe Cable Locator Variable Frequency Series User Manual...

Страница 2: ...ts reserved No part of this manual may be reproduced copied modified or adapted without the prior written consent of the SubSurface Instruments Inc Please contact SubSurface Instruments Inc to request...

Страница 3: ...e 14 Left Right Auto Gain Mode 15 Absolute Signal Strength 15 Gain Level Indication 15 Passive 50 60 Hz Locating 16 Passive Radio Frequency Locating 16 Passive Rectifier CP Locating 16 Push Button Dep...

Страница 4: ...by Products sold or supplied by SubSurface Instruments Inc Failure to follow these warning could result in serious injury or death Only persons qualified and trained to operate cable pipe locators ma...

Страница 5: ...se only Duracell alkaline batteries Note The battery type used must be selected in the programming menu of the transmitter and the receiver For instructions on how to select please see page 4 By regis...

Страница 6: ...normal operation The PL VF operating modes frequencies and other functions are user programmable and can be changed at anytime through a quick selection process in the programming menu To select the...

Страница 7: ...EL CONTROL The ON OFF OUTPUT SIGNAL LEVEL CONTROL turns the unit on With a short press it will adjust the power output from the Transmitter There are 3 selections on the standard power settings Holdin...

Страница 8: ...The Red Black Test Cord or the Ground Rod are not needed for this method Successful coupler operation requires an insulated conductor that is grounded on both near and far ends Loop the Flexicoupler...

Страница 9: ...rt tracing the path with the Receiver 25 feet from the Transmitter Search in the 90 zone as shown above Locate the cable or pipe and follow the path If the signal becomes weak move the Transmitter to...

Страница 10: ...work on the highest of the medium frequencies 33kHz and high frequencies Low Frequencies are usually preferred to the mid range frequencies and high frequencies because they are less susceptible to l...

Страница 11: ...rtain modes and some modes will only be available with certain frequencies The available selectable frequencies can be edited within the programing menu Mode Select A long press press and hold for 2 s...

Страница 12: ...start with the unit on Press and hold depressed the Function button Power On Off for 10 seconds Pro will display at the top of the LCD Using the Gain Down key scroll through the primary menu to PathL...

Страница 13: ...or a maximum signal As you move the Receiver away from the cable path the meter reading and audio frequency response will drop off The Left Right arrows operate off of the Null reading By utilizing th...

Страница 14: ...level higher or lower One of the following may occur a a junction where the signal divides and goes several directions b a break in the cable or shield c a change in the depth of the cable or pipe d...

Страница 15: ...inted This measurement can also be used to monitor signal loss as the conductor is being traced The Gain up and down buttons are used to increase and decrease the gain in small amounts If the meter re...

Страница 16: ...tilities where radio frequencies have coupled to the utility This mode is useful for sweeping a green area for utilities In certain circumstances this mode will locate water pipes cable television gas...

Страница 17: ...way to be sure of the depth of a utility is to expose the utility At any given time the depth readout may be inaccurate The following are methods and procedures that will aid in increasing the reliab...

Страница 18: ...the Bubble Level centered 4 When the receiver indicates a Null reading mark the location of the receiver s foot 5 The distance between the Receiver and the cable path is the depth of the pipe or cabl...

Страница 19: ...The PL VF Receiver contains a feature that is very useful in identifying a desired cable in a field of various conductors and or utilities It is not unusual for the target conductor the conductor conn...

Страница 20: ...recommended to allow the Sonde to move easier Or if you need to attach the Sonde to a sewer auger it is recommended you use duct tape and apply as the shown in the figure below If taping the Sonde on...

Страница 21: ...ting when the PEAK reading is found Then rotate the Receiver as shown in the figure below When pivoting the Receiver do not change the vertical position The Receiver will indicate a peak when the Rece...

Страница 22: ...e Sonde and find a NULL between the PEAK ghost signals Mark this point A Then move the Receiver along the path in front of the Sonde and find another NULL Mark this point B Next measure the distance b...

Страница 23: ...tween the ground rod and the fault the arrows will not properly display direction until the unit comes within range of the fault or ground rod SIGNAL STRENGTH The Signal Strength is displayed in a val...

Страница 24: ...AND DIRECTLY ABOVE THE CABLE PATH CABLE SIDE VIEW BOTH SPIKES SHOULD EVENLY PENETRATE THE GROUND AND MAKE GOOD ELECTRICAL CONTACT Set the Transmitter to fault mode by pressing and holding the frequenc...

Страница 25: ...iver with the GRP plug in the GRP to the jack in the handle of the receiver Then press and hold the mode button for 10 seconds to select the to select DFF mode Note numeric reading as reference to sig...

Страница 26: ...directional indication changes the fault will lie on a straight line projected at a right angle from the center of the GRP The GRP adjustments can be made by slightly rotating the Ground Return Probe...

Страница 27: ...mitter Receiver Operating Frequency Antenna Mode Audio Indication Operating Temperature Battery Type Battery Life Dimensions Weight Signal Strength Gain Control Dynamic Range Depth Measurement 200Hz 4...

Страница 28: ...2 A brief description of the trouble 3 A return shipping address billing mail address any special shipping instructions Packing Instructions Remove and discard all batteries Place the unit to be repa...

Отзывы: