23
ENGLISH
Functions during the dive
4.3.2 Preparation for the dive and function check
Switch on Subgear XP-3H by pushing
and check the test display:
Are all elements of the display activated? Do not use Subgear XP-3H if the
display does not show all elements. When switching on Subgear XP-3H with
, the test display will not appear.
WARNING
Check the battery capacity before each dive ->15.
4.4 Functions during the dive
4.4.1 Immersion
If the water contacts are deactivated (->70), switch on Subgear XP-3H before immersion.
WARNING
If you have chosen the option "Water contacts off" ("set 1" or Dive.Log), Subgear XP-3H will turn on
with a delay of up to 1 minute into the dive. This will affect functioning of the computer. Make sure
that the computer is on before starting the dive.
After immersion, starting at a depth of about 0.8m (3ft), all diving functions are monitored, i.e. depth,
tank pressure and dive time displayed, maximum depth stored, saturation of tissues calculated,
no-stop time or decompression prognosis determined, ascent rate controlled and displayed and the
correctness of the decompression procedure supervised.
4.4.2 Setting
bookmarks
During the dive you can create bookmarks in your dive profi le by pressing
. The logbook icon
appears for 4 seconds and an audible signal confi rms the creation of the bookmark. These bookmarks
will be graphically displayed in the dive profi le of Dive.Log.
4.4.3
Dive time
The whole time spent below a depth of 0.8m (3ft) is displayed as dive time
in minutes. The time above 0.8m (3ft) is counted as dive time only if the diver
descends again below 0.8m (3ft) within 5 minutes.
While the dive time is running, the colons on the right of the figures are flashing
in one second intervals. Maximum dive time displayed is 199 minutes.
WARNING
Half time alarm (turn around alarm)
If half of the set maximum dive time has elapsed, an audible signal goes off and
fl ashes for 1 minute.
WARNING
Set dive time has elapsed ->69
An audible signal goes off and the dive time starts fl ashing.
Dive time