– 34 –
CLAMP
STOP SWITCH WIRE
STOP SWITCH
2-3-21 STOP SWITCH
(1) Install stop switch to blower housing.
(2) Connect wires referring to the wiring diagram.
A
A
WASHER : 1 pc.
P.T.O. shaft side
M6 x 12 FLANGE
BOLT : 2 pcs.
M8 FLANGE NUT : 1 pc.
M6 FLANGE
NUT : 4 pcs.
FUEL TANK
BRACKET 2
FUEL TANK
BRACKET
2-3-22 FUEL TANK BRACKET 2
Attach washer (t=1.2) in position and then install fuel
bracket 2.
M8 flange nut : 1 pc.
2-3-23 FUEL TANK BRACKET
Set fuel tank bracket onto rocker cover installing
bolts.
M6 flange nut : 4 pcs.
Tighten flange bolts with fuel tank bracket 2.
M6 x 12 mm flange bolt : 2 pcs.
Tightening torque
17 - 19 N•m
(170 - 190 kgf•cm)
(12.3 - 13.7 ft•lb.)
Tightening torque
6 - 8 N•m
(60 - 80 kgf•cm)
(4.3 - 5.7 ft•lb.)
Tightening torque
6 - 8 N•m
(60 - 80 kgf•cm)
(4.3 - 5.7 ft•lb.)